Productprofil:

CYROLITE G-20 HIFLO compound is an impact-modified acrylic-based multipolymer for molding and extrusion of medical applications.

Typical properties of CYROLITE® acrylic-based multipolymer compounds are:


• excellent chemical resistance to fats and oils
• excellent bonding and welding capabilities
• excellent bonding to PVC tubing
• good impact strength
• good light transmission
• good resistance to EtO, gamma and E-beam sterilization

The special properties of CYROLITE G-20 HIFLO compound are:


• excellent melt flow rate
• good heat resistance

Application:

Used for injection molding and extrusion of medical devices, medical packaging, as well as toys and appliance parts.

Example:

Y-sites, luer connectors and check valves.

Processing:

CYROLITE G-20 HIFLO compound can be processed in injection molding machines and extrusion lines with 3- zone general purpose screws.

Physical Form / Packaging:

Available in 1500 lb. gaylord boxes; other packaging available on request.

Rheological propertiesValueUnitTest Standard
Melt volume-flow rate, MVR 6.2 cm³/10min ISO 1133
Temperature 230 °C ISO 1133
Load 3.8 kg ISO 1133
Mechanical propertiesValueUnitTest Standard
Tensile Modulus 2300 MPa ISO 527-1/-2
Yield stress 51 MPa ISO 527-1/-2
Yield strain 3.4 % ISO 527-1/-2
Nominal strain at break 11 % ISO 527-1/-2
Charpy impact strength, +23°C N kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 11 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
Temp. of deflection under load, 1.80 MPa 79 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 83 °C ISO 75-1/-2
Vicat softening temperature, 50°C/h 50N 95 °C ISO 306
Coeff. of linear therm. expansion, parallel 90 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB class IEC 60695-11-10
Thickness tested 1.6 mm IEC 60695-11-10
Oxygen index 18 % ISO 4589-1/-2
Electrical propertiesValueUnitTest Standard
Volume resistivity >1E13 Ohm*m IEC 60093
Surface resistivity 1E13 Ohm IEC 60093
Other propertiesValueUnitTest Standard
Humidity absorption 0.3 % Sim. to ISO 62
Density 1110 kg/m³ ISO 1183
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 240 °C ISO 294
Injection Molding, mold temperature 65 °C ISO 10724
Injection Molding, injection velocity 195 mm/s ISO 294
Characteristics
Processing
Injection Molding, Film Extrusion, Profile Extrusion, Other Extrusion, Thermoforming
Delivery form
Pellets
Special Characteristics
Transparent
Regional Availability
Other text information
Injection molding
PREPROCESSING
Predrying temperature: 80 °C
Predrying time: 3 - 4 h
PROCESSING
Min. melt temperature: 195 - 240°C
Min. mold temperature:50 - 80°C
Disclaimer
All listed technical data are typical values intended for your guidance.
They are given without obligation and do not constitute a materials
specification. Should you have any further questions concerning material
behavior or properties, please contact us at the following address :

for PA:           Evonik Industries AG
                     PP-HP-CRM
                     Gebäude 1227 / PB 16
                     D-45764 Marl
                     Phone: +49-(0)2365/49-2720
                     Fax:+49-(0)2365/49-2070
                     E-Mail: campusplastics@evonik.com

for PMMA:     Evonik Industries AG
                     Marketing / Campus
                     Kirschenallee
                     D-64293 Darmstadt
                     Germany
                     Phone: +49 - (0) 61 51 / 18-47 11
                     Fax: +49 - (0) 61 51 / 18-31 77
                     E-Mail: campusplastics@evonik.com
                     Internet: http://www.plexiglas-polymers.com

 

® = registered trademark

 

PLEXIGLAS® is a registered trademark of Evonik Röhm GmbH, Germany,

outside of the Americas. Within the Americas it is sold as ACRYLITE®,

which is a registered trademark of Evonik Cyro LLC, USA.

PLEXIMID® is a registered trademarks of Evonik Röhm GmbH, Germany.

CYROLITE® and XT® polymer are registered trademarks of Evonik Cyro LLC, USA.

 

This information and all further technical advice is based on our present knowledge

and experience. However, it implies no liability or other legal responsibility on our part,

including with regard to existing third party intellectual property rights, especially

patent rights. In particular, no warranty, whether express or implied, or guarantee of

product properties in the legal sense is intended or implied. We reserve the right to

make any changes according to technological progress or further developments. The

customer is not released from the obligation to conduct careful inspection and testing

of incoming goods. Performance of the product described herein should be verified by

testing, which should be carried out only by qualified experts in the sole responsibility

of a customer. Reference to trade names used by other companies is neither a

recommendation, nor does it imply that similar products could not be used.

 

NAFTA:

This information and all technical and other advice are based on Evonik’s

present knowledge and experience. However, Evonik assumes no liability for

such information or advice, including the extent to which such information or

advice may relate to third party intellectual property rights. Evonik reserves the

right to make any changes to information or advice at any time, without prior

or subsequent notice. EVONIK DISCLAIMS ALL REPRESENTATIONS AND

WARRANTIES, WHETHER EXPRESS OR IMPLIED, AND SHALL HAVE NO LIABILITY

FOR, MERCHANTABILITY OF THE PRODUCT OR ITS FITNESS FOR A PARTICULAR

PURPOSE (EVEN IF EVONIK IS AWARE OF SUCH PURPOSE), OR OTHERWISE.

EVONIK SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR

INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. It is the

customer’s sole responsibility to arrange for inspection and testing of all

products by qualified experts. Reference to trade names used by other

companies is neither a recommendation nor an endorsement of the

corresponding product, and does not imply that similar products could not be

used.

 

Sales range and technical data subject to alteration.

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012