View list of
  • All DuPont grades
  • All POM grades
  • All grades beginning with D

CAMPUS® datasheet | Delrin® 300ATB BK000


This datasheet of Delrin® 300ATB BK000 from DuPont Engineering Polymers is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

This datasheet includes:

  Delrin® 300ATB BK000 | POM-I-CD | DuPont Engineering Polymers
Rheological propertiesValueUnitTest Standard
Melt volume-flow rate (MVR) 1.9 cm³/10min ISO 1133
Temperature 190 °C ISO 1133
Load 2.16 kg ISO 1133
Molding shrinkage (parallel) 1.8 % ISO 294-4, 2577
Molding shrinkage (normal) 1.7 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
Tensile Modulus 2300 MPa ISO 527-1/-2
Stress at break 50 MPa ISO 527-1/-2
Strain at break 16 % ISO 527-1/-2
Charpy impact strength (+23°C) 130 kJ/m² ISO 179/1eU
Charpy impact strength (-30°C) 100 kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 8 kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 6 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
Melting temperature (10°C/min) 178 °C ISO 11357-1/-3
Temp. of deflection under load (1.80 MPa) 70 °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 135 °C ISO 75-1/-2
Coeff. of linear therm. expansion (parallel) 120 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion (normal) 120 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB class IEC 60695-11-10
Thickness tested 1.5 mm IEC 60695-11-10
Electrical propertiesValueUnitTest Standard
Volume resistivity 1000 Ohm*m IEC 60093
Surface resistivity 100000 Ohm IEC 60093
Other propertiesValueUnitTest Standard
Density 1410 kg/m³ ISO 1183
Rheological calculation propertiesValueUnitTest Standard
Density of melt 1210 kg/m³ -
Thermal conductivity of melt 0.25 W/(m K) -
Spec. heat capacity melt 2670 J/(kg K) -
Ejection temperature 135 °C -
Diagrams
Viscosity-shear rate , Delrin® 300ATB BK000, POM-I-CD, DuPont
Shearstress-shear rate , Delrin® 300ATB BK000, POM-I-CD, DuPont
Stress-strain , Delrin® 300ATB BK000, POM-I-CD, DuPont
Secant modulus-strain , Delrin® 300ATB BK000, POM-I-CD, DuPont
Specific volume-temperature (pvT) , Delrin® 300ATB BK000, POM-I-CD, DuPont
Tensile modulus-temperature , Delrin® 300ATB BK000, POM-I-CD, DuPont
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Release agent
Special Characteristics
Increased electrical conductivity, Anti-static
Regional Availability
Disclaimer

E.I. du Pont de Nemours and Company is pleased to provide information about its products with the CAMPUS electronic database.

The information provided is gratis and DuPont assumes no obligation or liability for any advice furnished or for any results obtained with respect to this information.

All such advice is given and accepted at the risk of the buyer. The disclosure of information herein is not an express or implied license to operate under any patent of DuPont or others.

DuPont warrants that the use or sale of any material which is described herein and is offered for sale by DuPont does not infringe any patent covering the material itself, but does not warrant against infringement by reason of the use thereof in combination with other materials or the operation of any process.

Unless otherwise noted, the property values are for natural color (NC010) resins only. Colorants or other additives may alter some or all of the properties.
The data listed herein fall within the normal range of product properties and they should not be used to establish specification limits nor used alone as the basis of design.

Material Safety Data Sheets (SDSs) can be obtained from local sales offices.

Products listed herein should not be used in medical applications involving permanent implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont under a written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use.

For further information, please contact your DuPont representative.

You may also request a copy of DuPont policy regarding medical applications H-50103-2 and DuPont caution regarding medical applications H-50102-2.

Products listed herein may from time to time be modified or removed.
Please call your local sales office to determine current availability.


The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991