  Durethan® AKV 35 CX H2.0 | PA66-GF35 | LANXESS Deutschland GmbH
Product Texts
PA 66, 35 % glass fibers, injection molding, heat aging stabilized
Rheological propertiesdry / condUnitTest Standard
Molding shrinkage (parallel) 0.3 / * % ISO 294-4, 2577
Molding shrinkage (normal) 0.9 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 11000 / - MPa ISO 527-1/-2
Stress at break 197 / - MPa ISO 527-1/-2
Strain at break 2.8 / - % ISO 527-1/-2
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 260 / * °C ISO 11357-1/-3
Other propertiesdry / condUnitTest Standard
Density 1410 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
Viscosity number 146 / * cm³/g ISO 307, 1157, 1628
Rheological calculation propertiesValueUnitTest Standard
Density of melt 1200 kg/m³ -
Thermal conductivity of melt 0.268 W/(m K) -
Spec. heat capacity melt 2180 J/(kg K) -
Eff. thermal diffusivity 1.03E-7 m²/s -
Ejection temperature 185 °C -
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 300 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 10724
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Disclaimer
This information and our  technical advice - whether verbal, in  writing
or by way of trials - are  given in good faith but without warranty, and
this  also  applies  where  proprietary  rights  of  third  parties  are
involved.  Our advice does not release you from  the obligation to check
its validity and to test our  products  as to their  suitability for the
intended processes and uses.  The  application, use  and  processing  of
our products and the products manufactured  by  you  on the basis of our
technical  advice  are  beyond our control and, therefore, entirely your
own  responsibility.  Our  products  are  sold  in  accordance  with our
General  Conditions of Sale and Delivery.
The values  stored in the databank should only be used as guidelines for
component   design.  In  giving  these  values  neither  guarantee,  nor
assurance of particular material properties can be given.

techcenter.lanxess.com

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991