View list of
  • All LANXESS grades
  • All PA6 grades
  • All grades beginning with D

CAMPUS® datasheet | Durethan® DP 1802 H3.0


This datasheet of Durethan® DP 1802 H3.0 from LANXESS Deutschland GmbH is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

This datasheet includes:

  Durethan® DP 1802 H3.0 | PA6 FR | LANXESS Deutschland GmbH
Product Texts
PA 6, non-reinforced, extrusion, injection moulding, halogen free flame retardant, impact modified
Rheological propertiesdry / condUnitTest Standard
Melt volume-flow rate (MVR) 8 / * cm³/10min ISO 1133
Temperature 260 / * °C ISO 1133
Load 5 / * kg ISO 1133
Molding shrinkage (parallel) 1.3 / * % ISO 294-4, 2577
Molding shrinkage (normal) 1.0 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 2500 / 750 MPa ISO 527-1/-2
Yield stress 65 / 30 MPa ISO 527-1/-2
Yield strain 3.9 / 25 % ISO 527-1/-2
Charpy impact strength (+23°C) 125 / N kJ/m² ISO 179/1eU
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 220 / * °C ISO 11357-1/-3
Temp. of deflection under load (1.80 MPa) 58 / * °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 156 / * °C ISO 75-1/-2
Coeff. of linear therm. expansion (parallel) 110 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion (normal) 100 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-2 / * class IEC 60695-11-10
Thickness tested 1.6 / * mm IEC 60695-11-10
Burning Behav. at thickness h V-2 / * class IEC 60695-11-10
Thickness tested 0.8 / * mm IEC 60695-11-10
Electrical propertiesdry / condUnitTest Standard
Electric strength 34 / - kV/mm IEC 60243-1
Comparative tracking index 600 / - - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 8 / * % Sim. to ISO 62
Density 1120 / - kg/m³ ISO 1183
Rheological calculation propertiesValueUnitTest Standard
Density of melt 970 kg/m³ -
Thermal conductivity of melt 0.183 W/(m K) -
Spec. heat capacity melt 2700 J/(kg K) -
Eff. thermal diffusivity 7E-8 m²/s -
Ejection temperature 140 °C -
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 280 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 10724
Characteristics
Processing
Injection Molding, Other Extrusion
Delivery form
Pellets
Additives
Lubricants, Plasticizer
Special Characteristics
Light stabilized or stable to light, Heat stabilized or stable to heat
Regional Availability
Disclaimer
This information and our  technical advice - whether verbal, in  writing
or by way of trials - are  given in good faith but without warranty, and
this  also  applies  where  proprietary  rights  of  third  parties  are
involved.  Our advice does not release you from  the obligation to check
its validity and to test our  products  as to their  suitability for the
intended processes and uses.  The  application, use  and  processing  of
our products and the products manufactured  by  you  on the basis of our
technical  advice  are  beyond our control and, therefore, entirely your
own  responsibility.  Our  products  are  sold  in  accordance  with our
General  Conditions of Sale and Delivery.
The values  stored in the databank should only be used as guidelines for
component   design.  In  giving  these  values  neither  guarantee,  nor
assurance of particular material properties can be given.

techcenter.lanxess.com

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.