This datasheet of EDISTIR® ICE R 830D from Polimeri Europa is provided by the international plastics database CAMPUS.
CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.
Designation: Thermoplastics ISO 2897-PS-I,G,088-03-07-12
Environmental stress cracking resistant (ESCR) HIPS.
ICE R 830D combines high impact strength with improved chemical resistance to oils, fats and chemical agents, such as detergents for both industrial and domestic use.
Developed in particular for the fridge sector where hydrocarbons are used as blowing agents for PU insulating foams.
Applications:
This grade is suitable for extrusion/thermoforming and injection moulding.
Typical applications are inner liners and frames for refrigerators and packaging containers for fatty foods. ICE R 830D significantly improves the wall thickness distribution in thermoforming and allows
to optimize the thickness of the original extruded sheet.
| Rheological properties | Value | Unit | Test Standard |
| Melt volume-flow rate (MVR) | 3.3 | cm³/10min | ISO 1133 |
| Temperature | 200 | °C | ISO 1133 |
| Load | 5 | kg | ISO 1133 |
| Mechanical properties | Value | Unit | Test Standard |
| Tensile Modulus | 1400 | MPa | ISO 527-1/-2 |
| Yield stress | 16 | MPa | ISO 527-1/-2 |
| Yield strain | 1.8 | % | ISO 527-1/-2 |
| Nominal strain at break | >50 | % | ISO 527-1/-2 |
| Charpy impact strength (+23°C) | N | kJ/m² | ISO 179/1eU |
| Charpy impact strength (-30°C) | 110 | kJ/m² | ISO 179/1eU |
| Charpy notched impact strength (+23°C) | 10.5 | kJ/m² | ISO 179/1eA |
| Charpy notched impact strength (-30°C) | 6 | kJ/m² | ISO 179/1eA |
| Thermal properties | Value | Unit | Test Standard |
| Glass transition temperature (10°C/min) | 94 | °C | ISO 11357-1/-2 |
| Temp. of deflection under load (1.80 MPa) | 70 | °C | ISO 75-1/-2 |
| Vicat softening temperature (50°C/h 50N) | 88 | °C | ISO 306 |
| Coeff. of linear therm. expansion (parallel) | 90 | E-6/K | ISO 11359-1/-2 |
| Burning Behav. at 1.5 mm nom. thickn. | HB | class | IEC 60695-11-10 |
| Thickness tested | 1.5 | mm | IEC 60695-11-10 |
| Electrical properties | Value | Unit | Test Standard |
| Relative permittivity (100Hz) | 2.5 | - | IEC 60250 |
| Relative permittivity (1MHz) | 2.5 | - | IEC 60250 |
| Dissipation factor (100Hz) | 3 | E-4 | IEC 60250 |
| Dissipation factor (1MHz) | 3 | E-4 | IEC 60250 |
| Volume resistivity | >1E13 | Ohm*m | IEC 60093 |
| Surface resistivity | >1E15 | Ohm | IEC 60093 |
| Electric strength | 65 | kV/mm | IEC 60243-1 |
| Other properties | Value | Unit | Test Standard |
| Water absorption | 0.06 | % | Sim. to ISO 62 |
| Humidity absorption | 0.04 | % | Sim. to ISO 62 |
| Density | 1040 | kg/m³ | ISO 1183 |
| Rheological calculation properties | Value | Unit | Test Standard |
| Density of melt | 950 | kg/m³ | - |
| Spec. heat capacity melt | 2050 | J/(kg K) | - |
| Test specimen production | Value | Unit | Test Standard |
| Processing conditions acc. ISO | 2900 | - | ISO ....-2 |
| Injection Molding, melt temperature | 220 | °C | ISO 294 |
| Injection Molding, mold temperature | 45 | °C | ISO 10724 |
| Injection Molding, injection velocity | 200 | mm/s | ISO 294 |
| Injection Molding, pressure at hold | 70 | MPa | ISO 294 |
PREPROCESSING
Drying normally not required
PROCESSING
Typical processing temperature range:
Melt temperature 210 - 260 °C
Mold temperature 20 - 60 °C
Drying normally not required
PROCESSING
Melt temperature 210 -240 °C
Drying normally not required
PROCESSING
Melt temperature 210 -240 °C
Drying normally not required
PROCESSING
Melt temperature 210 -240 °C
Dear CAMPUS User, The data, information and suggestions are provided for guidance purpose only. The Company accepts no responsibility for the results obtained therefrom, as neither for their utilisation in infringement of possible patents rights. All indicated data refer to natural grades. On the subject of the experimental products, the Company reserves the right to change without prewarning the characteristics, to optimise the performances. If you have any questions regarding CAMPUS, please send an e-mail to:Pe Campus For further information regarding Polimeri Europa: Polimeri Europa Homepage