FREE DOWNLOAD
Interested inCreating a Property Table?
The CAMPUS desktop version
offers extended functionality!CAMPUS® datasheet | ETPV 90A01HS BK001
This datasheet of ETPV 90A01HS BK001 from DuPont Engineering Polymers is provided by the international plastics database CAMPUS.
CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.
It is a high-performance elastomer, molecularly fused into a high-performance thermoplastic base resin.
Parts made of DuPont ETPV can withstand service temperatures up to 160°C, much higher than thermoplastic elastomers (TPEs).
Manufacturing is done on conventional plastics equipment -- up to 10 times faster than traditional rubber processing.
Rubber-like flexibility and toughness is retained down to -40°C.
Parts made of the new material are highly resistant to oil, grease and chemicals.
DuPont ETPV contains no extractables, so it is more storage stable than traditional elastomers. Like most thermoplastics, DuPont ETPV is fully recyclable.
| Rheological properties | Value | Unit | Test Standard |
| Melt volume-flow rate (MVR) | 30 | cm³/10min | ISO 1133 |
| Temperature | 250 | °C | ISO 1133 |
| Load | 10 | kg | ISO 1133 |
| Molding shrinkage (parallel) | 1.6 | % | ISO 294-4, 2577 |
| Molding shrinkage (normal) | 1.3 | % | ISO 294-4, 2577 |
| Mechanical properties | Value | Unit | Test Standard |
| Tensile Modulus | 70 | MPa | ISO 527-1/-2 |
| Stress at 50% strain | 7.1 | MPa | ISO 527-1/-2 |
| Stress at 10% elongation | 3.8 | MPa | ISO 527-1/-2 |
| Stress at 100% elongation | 7.6 | MPa | ISO 527-1/-2 |
| Stress at break TPE | 9 | MPa | ISO 527-1/-2 |
| Strain at break | >50 | % | ISO 527-1/-2 |
| Strain at break TPE | 180 | % | ISO 527-1/-2 |
| Tensile creep modulus (1h) | 50 | MPa | ISO 899-1 |
| Tensile creep modulus (1000h) | 35 | MPa | ISO 899-1 |
| Charpy impact strength (+23°C) | N | kJ/m² | ISO 179/1eU |
| Charpy notched impact strength (+23°C) | N | kJ/m² | ISO 179/1eA |
| Compression Set under constant strain (100°C) | 45 | % | ISO 815 |
| Thermal properties | Value | Unit | Test Standard |
| Melting temperature (10°C/min) | 203 | °C | ISO 11357-1/-3 |
| Glass transition temperature (10°C/min) | -25 | °C | ISO 11357-1/-2 |
| Burning Behav. at 1.5 mm nom. thickn. | HB | class | IEC 60695-11-10 |
| Thickness tested | 1.5 | mm | IEC 60695-11-10 |
| Other properties | Value | Unit | Test Standard |
| Density | 1120 | kg/m³ | ISO 1183 |
E.I. du Pont de Nemours and Company is pleased to provide information about its products with the CAMPUS electronic database.
The information provided is gratis and DuPont assumes no obligation or liability for any advice furnished or for any results obtained with respect to this information.
All such advice is given and accepted at the risk of the buyer. The disclosure of information herein is not an express or implied license to operate under any patent of DuPont or others.
DuPont warrants that the use or sale of any material which is described herein and is offered for sale by DuPont does not infringe any patent covering the material itself, but does not warrant against infringement by reason of the use thereof in combination with other materials or the operation of any process.
Unless otherwise noted, the property values are for natural color (NC010) resins only. Colorants or other additives may alter some or all of the properties.
The data listed herein fall within the normal range of product properties and they should not be used to establish specification limits nor used alone as the basis of design.
Material Safety Data Sheets (SDSs) can be obtained from local sales offices.
Products listed herein should not be used in medical applications involving permanent implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont under a written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use.
For further information, please contact your DuPont representative.
You may also request a copy of DuPont policy regarding medical applications H-50103-2 and DuPont caution regarding medical applications H-50102-2.
Products listed herein may from time to time be modified or removed.
Please call your local sales office to determine current availability.
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991