View list of
  • All Ticona grades
  • All PPS grades
  • All grades beginning with F

CAMPUS® datasheet | FORTRON MT9320C0


This datasheet of FORTRON MT9320C0 from Ticona is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

You may contact the supplier for more information about this grade.

This datasheet includes:

  FORTRON MT9320C0 | PPS | Ticona
Product Texts
Fortron MT9320C0 is an unfilled grade used for extrusion applications.
It demonstrates excellent chemical resistance and thermal stability as
well as a high melt strength. Components made of this grade may be
used for medical, dental, pharmaceutical, and certain food handling
applications. Fortron MT9320C0 is in compliance with ISO 10993, USP
Class VI and it is included in the Fortron Drug and Device Master Files
at the FDA. This grade complies with the FDA Food Contact Notification
(FCN-No. 40) for repeat-use applications.
Mechanical propertiesValueUnitTest Standard
Stress at break 85 MPa ISO 527-1/-2
Strain at break 6 % ISO 527-1/-2
Thermal propertiesValueUnitTest Standard
Melting temperature (10°C/min) 280 °C ISO 11357-1/-3
Glass transition temperature (10°C/min) 90 °C ISO 11357-1/-2
Temp. of deflection under load (1.80 MPa) 115 °C ISO 75-1/-2
Temp. of deflection under load (8.00 MPa) 95 °C ISO 75-1/-2
Electrical propertiesValueUnitTest Standard
Relative permittivity (1MHz) 2.8 - IEC 60250
Volume resistivity 1E13 Ohm*m IEC 60093
Other propertiesValueUnitTest Standard
Water absorption 0.02 % Sim. to ISO 62
Density 1350 kg/m³ ISO 1183
Characteristics
Processing
Injection Molding, Film Extrusion, Profile Extrusion, Sheet Extrusion, Other Extrusion
Delivery form
Pellets
Regional Availability
Disclaimer
NOTICE TO USERS: Values shown are based on testing
of laboratory test specimens and represent data that fall
within the standard range of properties for natural material.
These values alone do not represent a sufficient basis for
any part design and are not intended for use in
establishing maximum, minimum, or ranges of values for
specification purposes. Colorants or other additives may
cause significant variations in data values.

Properties of molded parts can be influenced by a wide
variety of factors including, but not limited to, material
selection, additives, part design, processing conditions and
environmental exposure. Any determination of the
suitability of a particular material and part design for any
use contemplated by the users and the manner of such
use is the sole responsibility of the users, who must assure
themselves that the material as subsequently processed
meets the needs of their particular product or use.

To the best of our knowledge, the information contained in
this publication is accurate; however, we do not assume
any liability whatsoever for the accuracy and completeness
of such information. The information contained in this
publication should not be construed as a promise or
guarantee of specific properties of our products. It is the
sole responsibility of the users to investigate whether any
existing patents are infringed by the use of the materials
mentioned in this publication.

Moreover, there is a need to reduce human exposure to
many materials to the lowest practical limits in view of
possible adverse effects. To the extent that any hazards
may have been mentioned in this publication, we neither
suggest nor guarantee that such hazards are the only ones
which exist. We recommend that persons intending to rely
on any recommendation or to use any equipment,
processing technique, or material mentioned in this
publication should satisfy themselves that they can meet
all applicable safety and health standards.

We strongly recommend that users seek and adhere to the
manufacturer's current instructions for handling each
material they use, and to entrust the handling of such
material to adequately trained personnel only. Please call
the telephone numbers listed for additional technical
information. Call Customer Services for the appropriate
Materials Safety Data Sheets (MSDS) before attempting to
process our products.

The products mentioned herein are not intended for use in
medical or dental implants.

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991