RADIFLAM® B RV250AE | PBT-GF25 FR | RadiciPlastics
Product Texts
DESIGNATION:
Thermoplastics ISO 7792-PBT, MFGRS, 09-080, GF25
BRIEF DESCRIPTION:
PBT Flame retardant injection moulding grade
25% Glass fibre reinforced.
For high stiffness components.
UL94 V0 rated at 0,8mm
Thermoplastics ISO 7792-PBT, MFGRS, 09-080, GF25
BRIEF DESCRIPTION:
PBT Flame retardant injection moulding grade
25% Glass fibre reinforced.
For high stiffness components.
UL94 V0 rated at 0,8mm
| Mechanical properties | Value | Unit | Test Standard |
| Tensile Modulus | 10100 | MPa | ISO 527-1/-2 |
| Stress at break | 95 | MPa | ISO 527-1/-2 |
| Strain at break | 1.4 | % | ISO 527-1/-2 |
| Charpy impact strength (+23°C) | 26 | kJ/m² | ISO 179/1eU |
| Charpy impact strength (-30°C) | 23 | kJ/m² | ISO 179/1eU |
| Charpy notched impact strength (+23°C) | 6.6 | kJ/m² | ISO 179/1eA |
| Charpy notched impact strength (-30°C) | 6 | kJ/m² | ISO 179/1eA |
| Thermal properties | Value | Unit | Test Standard |
| Melting temperature (10°C/min) | 225 | °C | ISO 11357-1/-3 |
| Temp. of deflection under load (1.80 MPa) | 195 | °C | ISO 75-1/-2 |
| Temp. of deflection under load (0.45 MPa) | 205 | °C | ISO 75-1/-2 |
| Vicat softening temperature (50°C/h 50N) | 205 | °C | ISO 306 |
| Burning Behav. at 1.5 mm nom. thickn. | V-0 | class | IEC 60695-11-10 |
| Thickness tested | 1.6 | mm | IEC 60695-11-10 |
| UL recognition | UL | - | - |
| Burning Behav. at thickness h | V-0 | class | IEC 60695-11-10 |
| Thickness tested | 0.8 | mm | IEC 60695-11-10 |
| UL recognition | UL | - | - |
| Electrical properties | Value | Unit | Test Standard |
| Volume resistivity | 1E13 | Ohm*m | IEC 60093 |
| Comparative tracking index | 250 | - | IEC 60112 |
| Other properties | Value | Unit | Test Standard |
| Water absorption | 0.3 | % | Sim. to ISO 62 |
| Humidity absorption | 0.1 | % | Sim. to ISO 62 |
| Density | 1620 | kg/m³ | ISO 1183 |
| Test specimen production | Value | Unit | Test Standard |
| Processing conditions acc. ISO | 7792 | - | ISO ....-2 |
| Injection Molding, melt temperature | 260 | °C | ISO 294 |
| Injection Molding, mold temperature | 80 | °C | ISO 10724 |
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Lubricants
Regional Availability
Other text information
Injection molding
PREPROCESSING
Pre-drying recommended.
Max. water content 0.04%
Drying temperature 110°C
Drying time 2-4h (dry air dryer)
PROCESSING
Melt temperature 260°C
Mold temperature 80°C
Pre-drying recommended.
Max. water content 0.04%
Drying temperature 110°C
Drying time 2-4h (dry air dryer)
PROCESSING
Melt temperature 260°C
Mold temperature 80°C
Disclaimer
This database provides the technical properties of thermoplastics produced and marketed by RADICI NOVACIPS and his subsidiaries companies: RADILON® A Polyamide 66 RADILON® S Polyamide 6 RADILON® CA Copolyamide 66/6 RADILON® CS Copolyamide 6 semiaromatic RADITER® B Poly(butylene terephthalate) RADIFLAM® A Polyamide 66, self-extinguishing RADIFLAM® S Polyamide 6, self-extinguishing RADIFLAM® B Polybutylene terephthalate, self-extinguishing HERAFLEX® A Stirenic Thermoplastic Elastomer SEBS HERAFLEX® E Ether-Ester Thermoplastic Elastomer HERAFLEX® B Stirenic Thermoplastic Elastomer SBS HERAFLEX® P Modified Polypropylene RADILENE® R Polyethylene and Polypropylene The data and graphs contained in this database were carried out by our Research Centers and shall in no event be held to constitute or imply any warranty, undertaking, express or implied commitment from our part.
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991