View list of

CAMPUS® datasheet | SCHULAMID® 6 MKF 4015


This datasheet of SCHULAMID® 6 MKF 4015 from A. Schulman GmbH is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

You may contact the supplier for more information about this grade.

This datasheet includes:

  SCHULAMID® 6 MKF 4015 | PA6-(MD+GF)40 | A. Schulman GmbH
Product Texts
40% glas fibre and mineral reinforced PA 6 with high mechanical strength and dimensional stability


Rheological propertiesdry / condUnitTest Standard
Molding shrinkage (parallel) 0.4 / * % ISO 294-4, 2577
Molding shrinkage (normal) 0.6 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 7000 / 4500 MPa ISO 527-1/-2
Stress at break 110 / 70 MPa ISO 527-1/-2
Strain at break 2 / 3 % ISO 527-1/-2
Charpy impact strength (+23°C) 50 / 75 kJ/m² ISO 179/1eU
Charpy impact strength (-30°C) 40 / 60 kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 8 / 13 kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 5 / 8 kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 221 / * °C ISO 11357-1/-3
Glass transition temperature (10°C/min) 42 / * °C ISO 11357-1/-2
Temp. of deflection under load (1.80 MPa) 180 / * °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 210 / * °C ISO 75-1/-2
Vicat softening temperature (50°C/h 50N) 210 / * °C ISO 306
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.5 / * mm IEC 60695-11-10
Electrical propertiesdry / condUnitTest Standard
Volume resistivity >1E13 / 1E10 Ohm*m IEC 60093
Surface resistivity * / >1E15 Ohm IEC 60093
Comparative tracking index - / 400 - IEC 60112
Other propertiesdry / condUnitTest Standard
Humidity absorption 1.9 / * % Sim. to ISO 62
Density 1450 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
Viscosity number 145 / * cm³/g ISO 307, 1157, 1628
Rheological calculation propertiesValueUnitTest Standard
Density of melt 1250 kg/m³ -
Thermal conductivity of melt 0.38 W/(m K) -
Eff. thermal diffusivity 7.70E-8 m²/s -
Ejection temperature 120 °C -
Test specimen productionValueUnitTest Standard
Processing conditions acc. ISO 1870 - ISO ....-2
Injection Molding, melt temperature 250 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 10724
Injection Molding, injection velocity 250 mm/s ISO 294
Injection Molding, pressure at hold 70 MPa ISO 294
Characteristics
Processing
Injection Molding
Delivery form
Granules
Additives
Release agent
Regional Availability
Other text information
Injection molding
Pretreatment
Predrying: 4-6h / 80°C

Processing:

Melttemperature250 - 280°C
Mouldtemperature60 - 90°C

Disclaimer
The properties given in this software are typical, non-binding
mean values found fpor injection moulded natural coloured test
bars. Pigments and other modification may alter these values.
The characteristic values are based on our know-how and experience.
They do not warrant any specific properties. All our products
must be subjected to in house tests and inspections by the user
before application. This applies above all with regard to their
suitability for a particular purpose. It also applies accordingly
for all other written or verbal information given by our personnel.
Our General Terms of Business apply in all other respects,
particulaly with regard to liability for material defects.

If there are questions to given information, to further
properties or further A. Schulman products please contact

                  A. Schulman GmbH
                  Huettenstrasse 211
                  50170 Kerpen
                  Tel: 02273 / 561-0
                  Contact: Dipl.-Ing. M. Berg
                           aschulman@de.aschulman.com
                           Subject: Material data

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991