SCHULAMID® 6 MV HI | PA6-I | A. Schulman GmbH
Product Texts
Increased impact modified PA 6 standard grade
| Rheological properties | dry / cond | Unit | Test Standard |
| Molding shrinkage (parallel) | 1.1 / * | % | ISO 294-4, 2577 |
| Mechanical properties | dry / cond | Unit | Test Standard |
| Tensile Modulus | 2600 / 1000 | MPa | ISO 527-1/-2 |
| Yield stress | 74 / 43 | MPa | ISO 527-1/-2 |
| Yield strain | 4.2 / 20 | % | ISO 527-1/-2 |
| Nominal strain at break | >50 / >50 | % | ISO 527-1/-2 |
| Charpy impact strength (+23°C) | N / N | kJ/m² | ISO 179/1eU |
| Charpy impact strength (-30°C) | N / N | kJ/m² | ISO 179/1eU |
| Charpy notched impact strength (+23°C) | 15 / 50 | kJ/m² | ISO 179/1eA |
| Charpy notched impact strength (-30°C) | 8 / 12 | kJ/m² | ISO 179/1eA |
| Thermal properties | dry / cond | Unit | Test Standard |
| Melting temperature (10°C/min) | 219 / * | °C | ISO 11357-1/-3 |
| Glass transition temperature (10°C/min) | 40 / * | °C | ISO 11357-1/-2 |
| Temp. of deflection under load (1.80 MPa) | 70 / * | °C | ISO 75-1/-2 |
| Temp. of deflection under load (0.45 MPa) | 190 / * | °C | ISO 75-1/-2 |
| Vicat softening temperature (50°C/h 50N) | 195 / * | °C | ISO 306 |
| Burning Behav. at 1.5 mm nom. thickn. | HB / * | class | IEC 60695-11-10 |
| Thickness tested | 1.5 / * | mm | IEC 60695-11-10 |
| UL recognition | UL / * | - | - |
| Electrical properties | dry / cond | Unit | Test Standard |
| Relative permittivity (100Hz) | 3.5 / 12 | - | IEC 60250 |
| Relative permittivity (1MHz) | 3.3 / 4.4 | - | IEC 60250 |
| Dissipation factor (100Hz) | 0.011 / 0.14 | E-4 | IEC 60250 |
| Dissipation factor (1MHz) | 0.019 / 0.09 | E-4 | IEC 60250 |
| Volume resistivity | >1E13 / 1E10 | Ohm*m | IEC 60093 |
| Surface resistivity | * / >1E15 | Ohm | IEC 60093 |
| Comparative tracking index | - / 600 | - | IEC 60112 |
| Other properties | dry / cond | Unit | Test Standard |
| Humidity absorption | 2.3 / * | % | Sim. to ISO 62 |
| Density | 1110 / - | kg/m³ | ISO 1183 |
| Rheological calculation properties | Value | Unit | Test Standard |
| Density of melt | 935 | kg/m³ | - |
| Thermal conductivity of melt | 0.25 | W/(m K) | - |
| Spec. heat capacity melt | 1600 | J/(kg K) | - |
| Eff. thermal diffusivity | 8E-8 | m²/s | - |
| Ejection temperature | 110 | °C | - |
| Test specimen production | Value | Unit | Test Standard |
| Processing conditions acc. ISO | 1870 | - | ISO ....-2 |
| Injection Molding, melt temperature | 250 | °C | ISO 294 |
| Injection Molding, mold temperature | 80 | °C | ISO 10724 |
| Injection Molding, injection velocity | 250 | mm/s | ISO 294 |
| Injection Molding, pressure at hold | 70 | MPa | ISO 294 |
Diagrams
Characteristics
Processing
Injection Molding
Delivery form
Granules
Additives
Release agent, Plasticizer
Regional Availability
Other text information
Injection molding
Pretreatment
Predrying: 4-6h / 80°C
Predrying: 4-6h / 80°C
Processing:
| Melttemperature | 250 - 270 | °C |
| Mouldtemperature | 60 - 90 | °C |
Disclaimer
The properties given in this software are typical, non-binding
mean values found fpor injection moulded natural coloured test
bars. Pigments and other modification may alter these values.
The characteristic values are based on our know-how and experience.
They do not warrant any specific properties. All our products
must be subjected to in house tests and inspections by the user
before application. This applies above all with regard to their
suitability for a particular purpose. It also applies accordingly
for all other written or verbal information given by our personnel.
Our General Terms of Business apply in all other respects,
particulaly with regard to liability for material defects.
If there are questions to given information, to further
properties or further A. Schulman products please contact
A. Schulman GmbH
Huettenstrasse 211
50170 Kerpen
Tel: 02273 / 561-0
Contact: Dipl.-Ing. M. Berg
aschulman@de.aschulman.com
Subject: Material data
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991