Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 3300 / 1000 MPa ISO 527-1/-2
Yield stress 100 / 55 MPa ISO 527-1/-2
Yield strain 10 / 20 % ISO 527-1/-2
Nominal strain at break 40 / >50 % ISO 527-1/-2
Tensile creep modulus, 1000h * / 550 MPa ISO 899-1
Charpy impact strength, +23°C N / N kJ/m² ISO 179/1eU
Charpy impact strength, -30°C N / N kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 10 / 35 kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 4 / 4 kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature, 10°C/min 295 / * °C ISO 11357-1/-3
Glass transition temperature, 10°C/min 75 / * °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 190 / * °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 280 / * °C ISO 75-1/-2
Vicat softening temperature, 50°C/h 50N 290 / * °C ISO 306
Coeff. of linear therm. expansion, parallel 85 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 110 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-2 / * class IEC 60695-11-10
Thickness tested 1.5 / * mm IEC 60695-11-10
UL recognition UL / * - -
Burning Behav. at thickness h V-2 / * class IEC 60695-11-10
Thickness tested 0.8 / * mm IEC 60695-11-10
UL recognition UL / * - -
Oxygen index 27 / * % ISO 4589-1/-2
Electrical propertiesdry / condUnitTest Standard
Relative permittivity, 100Hz 4 / 13 - IEC 60250
Relative permittivity, 1MHz 3.6 / 4.3 - IEC 60250
Dissipation factor, 100Hz 70 / 1400 E-4 IEC 60250
Dissipation factor, 1MHz 260 / 1000 E-4 IEC 60250
Volume resistivity 1E13 / 1E10 Ohm*m IEC 60093
Surface resistivity * / 1E14 Ohm IEC 60093
Electric strength 25 / 20 kV/mm IEC 60243-1
Comparative tracking index 600 / - - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 13.5 / * % Sim. to ISO 62
Humidity absorption 3.7 / * % Sim. to ISO 62
Density 1180 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
Viscosity number 175 / * cm³/g ISO 307, 1157, 1628
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding
Disclaimer
 All information supplied by or on behalf of DSM in relation to its
products, whether in the nature of data, recommendations or otherwise,
is supported by research and, in good faith, believed reliable, but DSM
assumes no liability and makes no warranties of any kind, express or
implied, including, but not limited to, those of title, merchantability,
fitness for a particular purpose or non-infringement or any warranty
arising from a course of dealing, usage, or trade practice whatsoever
in respect of application, processing or use made of the aforementioned
information or product. The user assumes all responsibility for the use
of all information provided and shall verify quality and other properties or
any consequence from the use of all such information.

Typical values are indicative only and are not to be construed as being
binding specifications.

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012