View list of
  • All Rhodia grades
  • All PA66 grades
  • All grades beginning with T

CAMPUS® datasheet | Technyl® A 32G1


This datasheet of Technyl® A 32G1 from Rhodia Polyamide Engineering Plastics is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

This datasheet includes:

  Technyl® A 32G1 | PA66 | Rhodia Polyamide Engineering Plastics
Product Texts

Polyamide 66, UL94 V-2, GWIT 775/0.8t, High tough, Heat stabilized for injection molding.

 

TECHNYL®A 32G1 is fit for electric/electronics sectors of industry, offering good GWIT character, UL-94 flammability and high tough properties.

This grade is widely used for

- Connector

This product is available in natural, black, gray and in colors on request.

Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 262 / * °C ISO 11357-1/-3
Burning Behav. at thickness h V-2 / * class IEC 60695-11-10
Thickness tested 0.8 / * mm IEC 60695-11-10
UL recognition UL / * - -
Electrical propertiesdry / condUnitTest Standard
Comparative tracking index 350 / - - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 0.75 / * % Sim. to ISO 62
Density 1350 / - kg/m³ ISO 1183
Test specimen productionValueUnitTest Standard
Injection Molding, mold temperature 80 °C ISO 10724
Diagrams
Stress-strain , Technyl® A 32G1, PA66, Rhodia
Secant modulus-strain , Technyl® A 32G1, PA66, Rhodia
Characteristics
Processing
Injection Molding
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding

The material is supplied in airtight bags, ready for use. In the case that the virgin material has absorbed moisture, it must be dried to a final moisture content less than 0.2% with a dehumidified air drying equipment at approx.80°C

 

Recommended moulding conditions:

 

Barrel temperatures:

-feed zone                     270-285°C            

-compression zone       275-290°C                               

-front zone                   280-295°C

 

Mould temperatures      60-80°C

Disclaimer
WARRANTY

 This information is supplied to assist you in your choice of the
 material best suited to your requirements and does not in any way
 constitute a product specification.

 The values given relate to unpigmented materials (natural colour).
 Pigmentation can alter results. The characteristics supplied are
 typical values. Our specialists are available to advise you on the
 values to be used in order to carry out calculations correctly on
 part dimensions.

 The information contained in this document is supplied in good
 faith. However it is given purely as an indication. It shall not be
 considered in any way as a formal commitment or warranty on our part,
 notably in respect of the eventual infringement of any rights of
 third parties who may use our products. We remain at your entire
 disposal to provide you with any information that you might require.


The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991