  Ultradur® S 4090 G2 | (PBT+ASA)-GF10 | BASF
Product Texts
Low-warpage, easy-flowing injection molding grade with 10 % glass fibres for technical parts, for which dimensional stability is very important (eg, housings, plug-and-socket connectors).

Abbreviated designation according to ISO 1043-1: PBT-ASA
CLASSIFICATION ACCORDING TO ISO 7792-1:
Moulding Compound ISO 7792-PBT-ASA, MGHLNR,11-050, GF10
Rheological propertiesValueUnitTest Standard
Melt volume-flow rate, MVR 35 cm³/10min ISO 1133
Temperature 275 °C ISO 1133
Load 2.16 kg ISO 1133
Mechanical propertiesValueUnitTest Standard
Tensile Modulus 4500 MPa ISO 527-1/-2
Stress at break 75 MPa ISO 527-1/-2
Strain at break 2.9 % ISO 527-1/-2
Tensile creep modulus, 1h 3500 MPa ISO 899-1
Tensile creep modulus, 1000h 3300 MPa ISO 899-1
Charpy impact strength, +23°C 37 kJ/m² ISO 179/1eU
Charpy impact strength, -30°C 24 kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 6 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
Melting temperature, 10°C/min 223 °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 105 °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 190 °C ISO 75-1/-2
Vicat softening temperature, 50°C/h 50N 150 °C ISO 306
Coeff. of linear therm. expansion, parallel 55 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB class IEC 60695-11-10
Thickness tested 1.6 mm IEC 60695-11-10
Burning Behav. at thickness h HB class IEC 60695-11-10
Thickness tested 0.8 mm IEC 60695-11-10
Electrical propertiesValueUnitTest Standard
Relative permittivity, 100Hz 3.6 - IEC 60250
Relative permittivity, 1MHz 3.4 - IEC 60250
Dissipation factor, 100Hz 31 E-4 IEC 60250
Dissipation factor, 1MHz 205 E-4 IEC 60250
Volume resistivity >1E13 Ohm*m IEC 60093
Surface resistivity 1E14 Ohm IEC 60093
Electric strength 39 kV/mm IEC 60243-1
Comparative tracking index 375 - IEC 60112
Other propertiesValueUnitTest Standard
Water absorption 0.4 % Sim. to ISO 62
Humidity absorption 0.2 % Sim. to ISO 62
Density 1310 kg/m³ ISO 1183
Material specific propertiesValueUnitTest Standard
Viscosity number 105 cm³/g ISO 307, 1157, 1628
Rheological calculation propertiesValueUnitTest Standard
Density of melt 1090 kg/m³ -
Thermal conductivity of melt 0.165 W/(m K) -
Spec. heat capacity of melt 2060 J/(kg K) -
Ejection temperature 160 °C -
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 270 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 10724
Injection Molding, injection velocity 200 mm/s ISO 294
Diagrams
Viscosity-shear rate , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Shearstress-shear rate , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Dynamic Shear modulus-temperature , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Stress-strain , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Secant modulus-strain , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Stress-strain (isochronous) 23°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Creep modulus-time 23°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Stress-strain (isochronous) 40°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Creep modulus-time 40°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Stress-strain (isochronous) 60°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Creep modulus-time 60°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Stress-strain (isochronous) 120°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Creep modulus-time 120°C, Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Specific volume-temperature (pvT) , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Tensile modulus-temperature , Ultradur® S 4090 G2, (PBT+ASA)-GF10, BASF
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Lubricants
Special Characteristics
Light stabilized or stable to light, U.V. stabilized or stable to weather, Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding
PREPROCESSING
Pre/Post-processing, max. allowed water content: .04 %
Pre/Post-processing, Pre-drying, Temperature: 80 - 120 °C
Pre/Post-processing, Pre-drying, Time: 4 h

PROCESSING
injection molding, Melt temperature, range: 250 - 275 °C
injection molding, Melt temperature, recommended: 270 °C
injection molding, Mold temperature, range: 60 - 100 °C
injection molding, Mold temperature, recommended: 80 °C
Disclaimer
The data contained in this publication are based on our current
knowledge and experience. In view of the many factors that may affect
processing and application of our product, these data do not relieve
processors from carrying out their own investigations and tests. Any
descriptions, drawings, photographs, data, proportions, weights etc.
given herein may change without prior information and do not constitute
the agreed contractual quality of the product. It is the responsibility
of the recipient of our products to ensure that any proprietary rights
and existing laws and legislation are observed. NO WARRANTIES OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OFMERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS
DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE
PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING
THEINTELLECTUAL PROPERTY RIGHTS OF OTHERS.

In order to check the availability of products please contact us or our
sales agency.


For more information about our products contact your local BASF
representative or

BASF SE
Dept. PM/K
Fax: 0621-60-49497
e-mail: e-mail

CAMPUS® is a registered trademark of CWFG (Chemie
Wirtschaftsfoerderungsgesellschaft GmbH, Frankfurt)

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012