VESTAKEEP® L 4000 G


VESTAKEEP® L 4000 G is a high viscosity, unreinforced polyether ether
ketone for injection molding and extrusion.
The semi-crystalline polymer features superior thermal and chemical resistance.
Parts made from VESTAKEEP® L 4000 G are self-extinguishing.


VESTAKEEP® L 4000 G can be processed on common machines for
thermoplastics.

 

Application example: Parts for the electrical industry,

                                   machinery construction and aerospace.

Rheological propertiesValueUnitTest Standard
Melt volume-flow rate (MVR) 12 cm³/10min ISO 1133
Temperature 380 °C ISO 1133
Load 5 kg ISO 1133
Molding shrinkage (parallel) 1.1 % ISO 294-4, 2577
Molding shrinkage (normal) 1.8 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
Tensile Modulus 3500 MPa ISO 527-1/-2
Yield stress 96 MPa ISO 527-1/-2
Yield strain 5 % ISO 527-1/-2
Nominal strain at break 30 % ISO 527-1/-2
Charpy impact strength (+23°C) N kJ/m² ISO 179/1eU
Charpy impact strength (-30°C) N kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 7 kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 6 kJ/m² ISO 179/1eA
Thermal propertiesValueUnitTest Standard
Melting temperature (10°C/min) 340 °C ISO 11357-1/-3
Temp. of deflection under load (1.80 MPa) 155 °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 205 °C ISO 75-1/-2
Vicat softening temperature (50°C/h 50N) 305 °C ISO 306
Coeff. of linear therm. expansion (parallel) 60 E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-0 class IEC 60695-11-10
Thickness tested 1.6 mm IEC 60695-11-10
Oxygen index 38 % ISO 4589-1/-2
Electrical propertiesValueUnitTest Standard
Relative permittivity (100Hz) 2.8 - IEC 60250
Relative permittivity (1MHz) 2.8 - IEC 60250
Dissipation factor (1MHz) 50 E-4 IEC 60250
Volume resistivity >1E13 Ohm*m IEC 60093
Surface resistivity 1E15 Ohm IEC 60093
Comparative tracking index 200 - IEC 60112
Other propertiesValueUnitTest Standard
Water absorption 0.5 % Sim. to ISO 62
Density 1300 kg/m³ ISO 1183
Rheological calculation propertiesValueUnitTest Standard
Thermal conductivity of melt 0.18 W/(m K) -
Spec. heat capacity melt 2110 J/(kg K) -
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 370 °C ISO 294
Injection Molding, mold temperature 180 °C ISO 10724
Injection Molding, injection velocity 200 mm/s ISO 294
Injection Molding, pressure at hold 120 MPa ISO 294
Diagrams
Stress-strain , VESTAKEEP® L 4000 G, PEEK, Evonik Degussa
Secant modulus-strain , VESTAKEEP® L 4000 G, PEEK, Evonik Degussa
Characteristics
Processing
Injection Molding, Film Extrusion, Other Extrusion
Delivery form
Pellets
Regional Availability
Other text information
Injection molding

PREPROCESSING INFORMATION
Maximum Water Content: 0.25 %
When the water content is exceeded, the resin must be dried.The drying time is dependent on the

drying temperature. In practice a drying time of 2 - 3 hours at a temperature of 150 - 160 °C (depen-

ding on the water content of the resin) has been found to be satisfactory. With the exeption of

fresh air dryers, all conventional dryers can be used.

PROCESSING INFORMATION

Melt Temperature:360 - 380°C
Mold Temperature:160 - 200°C

POSTPROCESSING INFORMATION

Tempering: Temperature:      200 °C

                 Tempering Time:     2 h

 

The level of internal strain in injection molded products can be reduced through tempering.

Film extrusion

PREPROCESSING INFORMATION
Maximum Water Content: 0.25 %
When the water content is exceeded, the resin must be dried.The drying time is dependent on the

drying temperature. In practice a drying time of 2 - 3 hours at a temperature of 150 - 160 °C (depen-

ding on the water content of the resin) has been found to be satisfactory. With the exeption of

fresh air dryers, all conventional dryers can be used.
PROCESSING INFORMATION
We r ecommend a linear tempearture profile for extrusion

Hopper:100 - 120°C
Temperature zone 1 - T-nozzle:350 - 380°C
Other extrusion

PREPROCESSING INFORMATION
Maximum Water Content: 0.25 %
When the water content is exceeded, the resin must be dried.The drying time is dependent on the

drying temperature. In practice a drying time of 2 - 3 hours at a temperature of 150 - 160 °C (depen-

ding on the water content of the resin) has been found to be satisfactory. With the exeption of

fresh air dryers, all conventional dryers can be used.

PROCESSING INFORMATION
We recommend a linear tempearture profile for extrusion

Hopper:100 - 120°C
Temperature zone 1 - T-nozzle:350 - 380°C
Disclaimer
With the following data, which reflect our current knowledge and experience,
we wish to describe possible applications, however this information is given
without guarantee or assurance of the appropriate properties for a specific
application.

The processor is not relieved of the responsibility for incoming quality control
nor from his own testing and analysis.

All data concerning product safety (EG-guideline, BGVV, FDA) are of principle
nature and can be limitied regarding migration, temperature and type of food.
They reflect the status as of Feb. 29, 2012. To insure that this data reflects the
current state, please contact our Product Safety Department.

Should you have any questions, wishes or suggestions about CAMPUS,
please refer to the following address:

  Link to Evonik Industries AG homepage

In any case, we hope you enjoy working with CAMPUS!

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991