- All Evonik Degussa grades
- All PA12 grades
- All grades beginning with V
FREE DOWNLOAD
Interested inCreating a Property Table?
The CAMPUS desktop version
offers extended functionality!CAMPUS® datasheet | VESTAMID LX9013 blk (sw)
This datasheet of VESTAMID LX9013 blk (sw) from Evonik Industries AG is provided by the international plastics database CAMPUS.
CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.
High-viscosity, plasticized PA12-Plastic resin for extrusion with extraordinary long-term heat
resistance under thermal load.
Resin: ISO 1874-PA12-HIP,EHL,22-004
Parts made of this material absorb only little moisture, thus leading to nearly unaffected dimensions and
properties at changing ambient conditions.
VESTAMID® LX9013 is suitable to produce flexible tubes that are impact-resistance also at low tempera-
tures. These tubes are permanently exposed to higher temperatures, e.g. in the engine compartment of
motor vehicles, particularly as fuel lines in diesel vehicles.
The material corresponds to the extrusion compound PA12-HIPHL, grade 1 acc DIN 73378 and meets the
requirement acc. DIN 74324 (black), ISO 7628 and SAE J844.
| Rheological properties | dry / cond | Unit | Test Standard |
| Molding shrinkage (parallel) | 0.4 / * | % | ISO 294-4, 2577 |
| Molding shrinkage (normal) | 1.5 / * | % | ISO 294-4, 2577 |
| Mechanical properties | dry / cond | Unit | Test Standard | ||||||||||||||||||||||||||||
| Tensile Modulus | 410 / - | MPa | ISO 527-1/-2 | ||||||||||||||||||||||||||||
| Charpy impact strength (+23°C) | N / - | kJ/m² | ISO 179/1eU | ||||||||||||||||||||||||||||
| Charpy impact strength (-30°C) | N / - | kJ/m² | ISO 179/1eU | ||||||||||||||||||||||||||||
| Charpy notched impact strength (+23°C) | 140[P] / - | kJ/m² | ISO 179/1eA | ||||||||||||||||||||||||||||
| Charpy notched impact strength (-30°C) | 7 / - | kJ/m² | ISO 179/1eA | ||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| Thermal properties | dry / cond | Unit | Test Standard |
| Melting temperature (10°C/min) | 172 / * | °C | ISO 11357-1/-3 |
| Temp. of deflection under load (1.80 MPa) | 55 / * | °C | ISO 75-1/-2 |
| Temp. of deflection under load (0.45 MPa) | 130 / * | °C | ISO 75-1/-2 |
| Vicat softening temperature (50°C/h 50N) | 130 / * | °C | ISO 306 |
| Burning Behav. at 1.5 mm nom. thickn. | HB / * | class | IEC 60695-11-10 |
| Thickness tested | 1.6 / * | mm | IEC 60695-11-10 |
| Burning Behav. at thickness h | HB / * | class | IEC 60695-11-10 |
| Thickness tested | 3.2 / * | mm | IEC 60695-11-10 |
| Electrical properties | dry / cond | Unit | Test Standard |
| Relative permittivity (100Hz) | 12 / - | - | IEC 60250 |
| Relative permittivity (1MHz) | 3.4 / - | - | IEC 60250 |
| Dissipation factor (100Hz) | 5000 / - | E-4 | IEC 60250 |
| Dissipation factor (1MHz) | 1000 / - | E-4 | IEC 60250 |
| Volume resistivity | 1E8 / - | Ohm*m | IEC 60093 |
| Electric strength | 25 / - | kV/mm | IEC 60243-1 |
| Comparative tracking index | 600 / - | - | IEC 60112 |
| Other properties | dry / cond | Unit | Test Standard |
| Humidity absorption | 0.6 / * | % | Sim. to ISO 62 |
| Density | 1020 / 1020 | kg/m³ | ISO 1183 |
| Test specimen production | Value | Unit | Test Standard |
| Injection Molding, melt temperature | 240 | °C | ISO 294 |
| Injection Molding, mold temperature | 80 | °C | ISO 10724 |
| Injection Molding, injection velocity | 200 | mm/s | ISO 294 |
| Injection Molding, pressure at hold | 70 | MPa | ISO 294 |
PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
When the indicated water content is exceeded, the resin must be dried. The drying time is dependent
on the drying temperature. At a drying temperature of 80 °C we recommend, depending on the water
content, a drying time of 8 - 16 hours. Fresh air dryers are acceptable, better would be a dry air or
vacuum dryer. Please note our product literature, plasticized resins can lose plasticizer during drying.
PROCESSING INFORMATION
Melt Temperature : 220 - 250 °C
With the following data, which reflect our current knowledge and experience, we wish to describe possible applications, however this information is given without guarantee or assurance of the appropriate properties for a specific application. The processor is not relieved of the responsibility for incoming quality control nor from his own testing and analysis. All data concerning product safety (EG-guideline, BGVV, FDA) are of principle nature and can be limitied regarding migration, temperature and type of food. They reflect the status as of Feb. 29, 2012. To insure that this data reflects the current state, please contact our Product Safety Department. Should you have any questions, wishes or suggestions about CAMPUS, please refer to the following address: Link to Evonik Industries AG homepage In any case, we hope you enjoy working with CAMPUS!
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991