Conductive nylon12 for use in multilayer tubing
Resin: ISO 1874-PA12-HIP,EHLZ,22-005
VESTAMID® LX9102 is a specially modified electrically conductive nylon 12 for use in conductive
multilayer tubing. VESTAMID® LX9102 can be used e.g. in multilayer tubing MLT 140.2 and
MLT 2040.2.
Compared to common conductive resins VESTAMID® LX9102 is characterised by a lower melt
viscosity and thus excellent extrudability also in thin layers. Use of VESTAMID® LX9102 leads to
tubing with excellent quality of the inner surface.
Multilayer tubing with an innermost layer made of VESTAMID® LX9102 complies with the American
automotive manufactures' requirements to avoid electrostatic charging generated by fuel flow.
| Rheological properties | dry / cond | Unit | Test Standard |
| Molding shrinkage (parallel) | 1.4 / * | % | ISO 294-4, 2577 |
| Molding shrinkage (normal) | 1.5 / * | % | ISO 294-4, 2577 |
| Mechanical properties | dry / cond | Unit | Test Standard | ||||||||||||||||||||||||||||
| Tensile Modulus | 640 / - | MPa | ISO 527-1/-2 | ||||||||||||||||||||||||||||
| Yield stress | 32 / - | MPa | ISO 527-1/-2 | ||||||||||||||||||||||||||||
| Yield strain | 37 / - | % | ISO 527-1/-2 | ||||||||||||||||||||||||||||
| Nominal strain at break | >50 / - | % | ISO 527-1/-2 | ||||||||||||||||||||||||||||
| Charpy impact strength (+23°C) | N / - | kJ/m² | ISO 179/1eU | ||||||||||||||||||||||||||||
| Charpy impact strength (-30°C) | N / - | kJ/m² | ISO 179/1eU | ||||||||||||||||||||||||||||
| Charpy notched impact strength (+23°C) | 90[P] / - | kJ/m² | ISO 179/1eA | ||||||||||||||||||||||||||||
| Charpy notched impact strength (-30°C) | 5 / - | kJ/m² | ISO 179/1eA | ||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| Thermal properties | dry / cond | Unit | Test Standard |
| Melting temperature (10°C/min) | 171 / * | °C | ISO 11357-1/-3 |
| Temp. of deflection under load (1.80 MPa) | 55 / * | °C | ISO 75-1/-2 |
| Temp. of deflection under load (0.45 MPa) | 120 / * | °C | ISO 75-1/-2 |
| Vicat softening temperature (50°C/h 50N) | 136 / * | °C | ISO 306 |
| Burning Behav. at 1.5 mm nom. thickn. | HB / * | class | IEC 60695-11-10 |
| Thickness tested | 1.6 / * | mm | IEC 60695-11-10 |
| Burning Behav. at thickness h | HB / * | class | IEC 60695-11-10 |
| Thickness tested | 3.2 / * | mm | IEC 60695-11-10 |
| Electrical properties | dry / cond | Unit | Test Standard |
| Volume resistivity | 100 / - | Ohm*m | IEC 60093 |
| Other properties | dry / cond | Unit | Test Standard |
| Water absorption | 1.5 / * | % | Sim. to ISO 62 |
| Humidity absorption | 0.5 / * | % | Sim. to ISO 62 |
| Density | 1120 / - | kg/m³ | ISO 1183 |
PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
When the indicated water content is exceeded, the resin must be dried. The drying time is dependent
on the drying temperature. At a drying temperature of 80 °C we recommend, depending on the water
content, a drying time of 8 - 16 hours. Fresh air dryers are acceptable, better would be a dry air or
vacuum dryer. Please note our product literature, plasticized resins can lose plasticizer during drying.
PROCESSING INFORMATION
Melt Temperature : 230 - 260 °C
With the following data, which reflect our current knowledge and experience, we wish to describe possible applications, however this information is given without guarantee or assurance of the appropriate properties for a specific application. The processor is not relieved of the responsibility for incoming quality control nor from his own testing and analysis. All data concerning product safety (EG-guideline, BGVV, FDA) are of principle nature and can be limitied regarding migration, temperature and type of food. They reflect the status as of Feb. 29, 2012. To insure that this data reflects the current state, please contact our Product Safety Department. Should you have any questions, wishes or suggestions about CAMPUS, please refer to the following address: Link to Evonik Industries AG homepage In any case, we hope you enjoy working with CAMPUS!
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991