View list of

CAMPUS® datasheet | VESTAMID X7099 blk (sw)


This datasheet of VESTAMID X7099 blk (sw) from Evonik Industries AG is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

You may contact the supplier for more information about this grade.

This datasheet includes:

  VESTAMID® X7099 blk (sw) | PA612-GF20 | Evonik Industries AG
Product Texts
VESTAMID® X7099 blk


Resin: ISO 1874-PA612,MH,14-060,GF20

 

VESTAMID® X7099 is a PA 612 resin especially developed for the production of plastic-rubber

composites according to the Evonik Industries K&K Process patent.


Parts made from VESTAMID® X7099 can be, without the use of adhesives or adhesion promoters,

covulcanized with rubbers, such as XNBR, HNBR, AEM or FPM.


As a partially crystalline resin VESTAMID® X7099 exhibits an outstanding chemical resistance,

especially against fuels, oils and fats.


In comparison to resins based on PA 66 or PA 6 VESTAMID® X7099 has a distinctly lower water

absorption.

 

Rheological propertiesdry / condUnitTest Standard
Melt volume-flow rate (MVR) 10 / * cm³/10min ISO 1133
Temperature 275 / * °C ISO 1133
Load 5 / * kg ISO 1133
Molding shrinkage (parallel) 0.6 / * % ISO 294-4, 2577
Molding shrinkage (normal) 1.1 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 5600 / - MPa ISO 527-1/-2
Stress at break 118 / - MPa ISO 527-1/-2
Strain at break 5 / - % ISO 527-1/-2
Charpy impact strength (+23°C) 80 / - kJ/m² ISO 179/1eU
Charpy impact strength (-30°C) 60 / - kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 10 / - kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 7 / - kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 215 / * °C ISO 11357-1/-3
Temp. of deflection under load (1.80 MPa) 190 / * °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 210 / * °C ISO 75-1/-2
Vicat softening temperature (50°C/h 50N) 205 / * °C ISO 306
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.6 / * mm IEC 60695-11-10
Burning Behav. at thickness h HB / * class IEC 60695-11-10
Thickness tested 3.2 / * mm IEC 60695-11-10
Electrical propertiesdry / condUnitTest Standard
Relative permittivity (100Hz) 4.4 / - - IEC 60250
Relative permittivity (1MHz) 3.9 / - - IEC 60250
Dissipation factor (100Hz) 650 / - E-4 IEC 60250
Dissipation factor (1MHz) 430 / - E-4 IEC 60250
Volume resistivity 1E12 / - Ohm*m IEC 60093
Electric strength 38 / - kV/mm IEC 60243-1
Other propertiesdry / condUnitTest Standard
Water absorption 2 / * % Sim. to ISO 62
Humidity absorption 0.8 / * % Sim. to ISO 62
Density 1200 / 1200 kg/m³ ISO 1183
Rheological calculation propertiesValueUnitTest Standard
Density of melt 1050 kg/m³ -
Thermal conductivity of melt 0.2 W/(m K) -
Spec. heat capacity melt 2590 J/(kg K) -
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 270 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 10724
Injection Molding, injection velocity 200 mm/s ISO 294
Injection Molding, pressure at hold 70 MPa ISO 294
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
When the indicated water content is exceeded, the resin must be dried. The drying time is dependent

on the drying temperature. At a drying temperature of 80 °C we recommend, depending on the water

content, a drying time of 8 - 16 hours. Fresh air dryers are acceptable, better would be a dry air or

vacuum dryer. Please note our product literature, plasticized resins can lose plasticizer during drying.


PROCESSING INFORMATION
Melt Temperature : 230 - 270 °C

Mold Temperature :  50 - 100 °C

Disclaimer
With the following data, which reflect our current knowledge and experience,
we wish to describe possible applications, however this information is given
without guarantee or assurance of the appropriate properties for a specific
application.

The processor is not relieved of the responsibility for incoming quality control
nor from his own testing and analysis.

All data concerning product safety (EG-guideline, BGVV, FDA) are of principle
nature and can be limitied regarding migration, temperature and type of food.
They reflect the status as of Feb. 29, 2012. To insure that this data reflects the
current state, please contact our Product Safety Department.

Should you have any questions, wishes or suggestions about CAMPUS,
please refer to the following address:

  Link to Evonik Industries AG homepage

In any case, we hope you enjoy working with CAMPUS!

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.