View list of

CAMPUS® datasheet | VESTORAN 1900 blk (sw) 2.7024


This datasheet of VESTORAN 1900 blk (sw) 2.7024 from Evonik Industries AG is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

You may contact the supplier for more information about this grade.

This datasheet includes:

  VESTORAN® 1900 blk (sw) 2.7024 | PPE-I | Evonik Industries AG
Product Texts
VESTORAN® 1900 blk 2.7024


Unfilled, amorphous PPE resin.

As a material of amorphous structure VESTORAN® 1900 blk 2.7024 shows very small mold shrinkage. Therefore

molded parts have a very low tendency to warp. The impact modified compound is of low density and easy to

process. Further properties are excellent impact strength, heat deflection under load and suitability for being

coated with lacquers.
Moldings of VESTORAN® 1900 blk 2.7024 are dimensionally stable and hydrolysis resistant even in hot water, but

are more sensitive to organic solvents than semi-crystalline plastics. VESTORAN® 1900 blk 2.7024 is resistant to

aqueous alkalines and acides, certain alcohols, and glycol solutions.

VESTORAN® 1900 blk 2.7024 is particularly suitable for the adhesion promoter-free manufacturing of plastic/ rubber

composites by the Evonik Industries AG -patented K&K process.
VESTORAN® 1900 blk 2.7024 is supplied as cylindrical granules in PE-bags.

Rheological propertiesValueUnitTest Standard
Melt volume-flow rate (MVR) 40 cm³/10min ISO 1133
Temperature 300 °C ISO 1133
Load 21.6 kg ISO 1133
Molding shrinkage (parallel) 0.9 % ISO 294-4, 2577
Molding shrinkage (normal) 0.8 % ISO 294-4, 2577
Mechanical propertiesValueUnitTest Standard
Tensile Modulus 2000 MPa ISO 527-1/-2
Yield stress 60 MPa ISO 527-1/-2
Yield strain 6 % ISO 527-1/-2
Nominal strain at break >50 % ISO 527-1/-2
Tensile creep modulus (1h) 2000 MPa ISO 899-1
Tensile creep modulus (1000h) 2000 MPa ISO 899-1
Charpy impact strength (+23°C) 250 kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 25 kJ/m² ISO 179/1eA
Tensile notched impact strength (+23°C) 110 kJ/m² ISO 8256/1
Thermal propertiesValueUnitTest Standard
Temp. of deflection under load (1.80 MPa) 170 °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 190 °C ISO 75-1/-2
Vicat softening temperature (50°C/h 50N) 190 °C ISO 306
Coeff. of linear therm. expansion (parallel) 80 E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion (normal) 80 E-6/K ISO 11359-1/-2
Electrical propertiesValueUnitTest Standard
Relative permittivity (100Hz) 2.6 - IEC 60250
Relative permittivity (1MHz) 2.9 - IEC 60250
Dissipation factor (100Hz) 8 E-4 IEC 60250
Dissipation factor (1MHz) 16 E-4 IEC 60250
Volume resistivity >1E13 Ohm*m IEC 60093
Surface resistivity 2E14 Ohm IEC 60093
Electric strength 40 kV/mm IEC 60243-1
Comparative tracking index 225 - IEC 60112
Other propertiesValueUnitTest Standard
Density 1040 kg/m³ ISO 1183
Rheological calculation propertiesValueUnitTest Standard
Density of melt 900 kg/m³ -
Thermal conductivity of melt 0.21 W/(m K) -
Spec. heat capacity melt 1910 J/(kg K) -
Ejection temperature 200 °C -
Test specimen productionValueUnitTest Standard
Injection Molding, melt temperature 320 °C ISO 294
Injection Molding, mold temperature 80 °C ISO 10724
Injection Molding, injection velocity 200 mm/s ISO 294
Diagrams
Viscosity-shear rate , VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Shearstress-shear rate , VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Dynamic Shear modulus-temperature , VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Stress-strain , VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Secant modulus-strain , VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Stress-strain (isochronous) 23°C, VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Creep modulus-time 23°C, VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Specific volume-temperature (pvT) , VESTORAN® 1900 blk (sw) 2.7024, PPE-I, Evonik Degussa
Characteristics
Processing
Injection Molding, Film Extrusion, Profile Extrusion, Sheet Extrusion, Other Extrusion, Blow Molding, Thermoforming
Delivery form
Pellets
Special Characteristics
Platable, Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
If the given water content is exceeded or silver streaks appear on the surface of parts, the resin should be dried.

Drying should be carried out is a dry air or vacuum dryer for at least 3 to 4 hours at 90 - 120°C. The resin should

be pre-heated to 80 - 110°C before molding. If a vented plastizier zone employed preheating can be omitted.
Please refer to our product information sheets!

PROCESSING INFORMATION

Melt Temperature:280 - 320°C
Mold Temperature:70 - 120°C
In a one step K&K Process the mold temperature can be increased up to 180°C.
Film extrusion

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
If the given water content is exceeded or silver streaks appear on the surface of parts, the resin should be dried.

Drying should be carried out is a dry air or vacuum dryer for at least 3 to 4 hours at 90 - 120°C. The resin should

be pre-heated to 80 - 110°C before molding. If a vented plastizier zone employed preheating can be omitted.
Please refer to our product information sheets!

PROCESSING INFORMATION
Melt Temperature : 275 - 290 °C

Other extrusion

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
If the given water content is exceeded or silver streaks appear on the surface of parts, the resin should be dried.

Drying should be carried out is a dry air or vacuum dryer for at least 3 to 4 hours at 90 - 120°C. The resin should

be pre-heated to 80 - 110°C before molding. If a vented plastizier zone employed preheating can be omitted.
Please refer to our product information sheets!


PROCESSING INFORMATION
Melt Temperature : 275 - 290 °C

Profile extrusion

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
If the given water content is exceeded or silver streaks appear on the surface of parts, the resin should be dried.

Drying should be carried out is a dry air or vacuum dryer for at least 3 to 4 hours at 90 - 120°C. The resin should

be pre-heated to 80 - 110°C before molding. If a vented plastizier zone employed preheating can be omitted.
Please refer to our product information sheets!

PROCESSING INFORMATION
Melt Temperature : 275 - 290 °C

Sheet extrusion

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
If the given water content is exceeded or silver streaks appear on the surface of parts, the resin should be dried.

Drying should be carried out is a dry air or vacuum dryer for at least 3 to 4 hours at 90 - 120°C. The resin should

be pre-heated to 80 - 110°C before molding. If a vented plastizier zone employed preheating can be omitted.
Please refer to our product information sheets!

PROCESSING INFORMATION
Melt Temperature : 275 - 290 °C

Blow molding

PREPROCESSING INFORMATION
Maximum Water Content: 0.1 %
If the given water content is exceeded or silver streaks appear on the surface of parts, the resin should be dried.

Drying should be carried out is a dry air or vacuum dryer for at least 3 to 4 hours at 90 - 120°C. The resin should

be pre-heated to 80 - 110°C before molding. If a vented plastizier zone employed preheating can be omitted.
Please refer to our product information sheets!

PROCESSING INFORMATION
Melt Temperature : 275 - 290 °C

Disclaimer
With the following data, which reflect our current knowledge and experience,
we wish to describe possible applications, however this information is given
without guarantee or assurance of the appropriate properties for a specific
application.

The processor is not relieved of the responsibility for incoming quality control
nor from his own testing and analysis.

All data concerning product safety (EG-guideline, BGVV, FDA) are of principle
nature and can be limitied regarding migration, temperature and type of food.
They reflect the status as of Feb. 29, 2012. To insure that this data reflects the
current state, please contact our Product Safety Department.

Should you have any questions, wishes or suggestions about CAMPUS,
please refer to the following address:

  Link to Evonik Industries AG homepage

In any case, we hope you enjoy working with CAMPUS!

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991