View list of

CAMPUS® datasheet | Zytel® HTN51G50HSL BK083


This datasheet of Zytel® HTN51G50HSL BK083 from DuPont Engineering Polymers is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

This datasheet includes:

  Zytel® HTN51G50HSL BK083 | PA6T/XT-GF50 | DuPont Engineering Polymers
Product Texts
Common features of Zytel® nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness and toughness, good high temperature performance, good electrical and flammability properties, good abrasion and chemical resistance.

Zytel® HTN cost effectively bridges the performance gap between conventional engineering resins and high-end specialty polymers – this is especially important when your component or system has to survive in a hot, cold, chemically aggressive and/or load-bearing environments.
Based on aromatic copolymers, Zytel® HTN offers a balance of chemical, moisture and temperature resistance, plus outstanding processability.

The good melt stability of Zytel® HTN normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (-31kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.

______________________________________________________


Zytel® HTN51G50HSL is a 50% glass fiber reinforced, heat stabilized and lubricated high performance polyamide resin for injection molding. It has excellent dimensional stability, excellent temperature resistance and low moisture absorption.

Rheological propertiesdry / condUnitTest Standard
Molding shrinkage (parallel) 0.2 / * % ISO 294-4, 2577
Molding shrinkage (normal) 0.5 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 18000 / 18000 MPa ISO 527-1/-2
Stress at break 260 / 250 MPa ISO 527-1/-2
Strain at break 2.1 / 2.1 % ISO 527-1/-2
Charpy impact strength (+23°C) 80 / - kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 15 / - kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 15 / - kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 300 / * °C ISO 11357-1/-3
Glass transition temperature (10°C/min) 150 / * °C ISO 11357-1/-2
Temp. of deflection under load (1.80 MPa) 265 / * °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 275 / * °C ISO 75-1/-2
Coeff. of linear therm. expansion (parallel) 14 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion (normal) 48 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.5 / * mm IEC 60695-11-10
Burning Behav. at thickness h HB / * class IEC 60695-11-10
Thickness tested 0.8 / * mm IEC 60695-11-10
Oxygen index 24 / * % ISO 4589-1/-2
Other propertiesdry / condUnitTest Standard
Density 1640 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
Viscosity number 100 / * cm³/g ISO 307, 1157, 1628
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Lubricants, Release agent
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding

PREPROCESSING


Drying Recommended = Yes, if moisture content of resin exceeds recommended level
Drying Temperature = 100°C
Drying Time, Dehumidified Dryer = 6-8 h
Processing Moisture Content = <0.1 %


PROCESSING


Melt Temperature Optimum = 325°C
Melt Temperature Range = 320-330°C
Mold Temperature Optimum = 150°C
Mold Temperature Range = 140-160°C
Maximum Screw tangential Speed : 0.15 m/s
Flow front speed : 300 mm/s
Hold pressure optimum : 85 MPa
Hold pressure range : 50-100 MPa
Back pressure : low
Hold pressure time : 3.5 s/mm
Maximum hold-up time : 10 min


Moulding guide

Disclaimer

E.I. du Pont de Nemours and Company is pleased to provide information about its products with the CAMPUS electronic database.

The information provided is gratis and DuPont assumes no obligation or liability for any advice furnished or for any results obtained with respect to this information.

All such advice is given and accepted at the risk of the buyer. The disclosure of information herein is not an express or implied license to operate under any patent of DuPont or others.

DuPont warrants that the use or sale of any material which is described herein and is offered for sale by DuPont does not infringe any patent covering the material itself, but does not warrant against infringement by reason of the use thereof in combination with other materials or the operation of any process.

Unless otherwise noted, the property values are for natural color (NC010) resins only. Colorants or other additives may alter some or all of the properties.
The data listed herein fall within the normal range of product properties and they should not be used to establish specification limits nor used alone as the basis of design.

Material Safety Data Sheets (SDSs) can be obtained from local sales offices.

Products listed herein should not be used in medical applications involving permanent implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont under a written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use.

For further information, please contact your DuPont representative.

You may also request a copy of DuPont policy regarding medical applications H-50103-2 and DuPont caution regarding medical applications H-50102-2.

Products listed herein may from time to time be modified or removed.
Please call your local sales office to determine current availability.


The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991