Rheological propertiesdry / condUnitTest Standard
Molding shrinkage, parallel 0.2 / * % ISO 294-4, 2577
Molding shrinkage, normal 0.7 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 16000 / 13000 MPa ISO 527-1/-2
Stress at break 220 / 170 MPa ISO 527-1/-2
Strain at break 2.2 / 2.5 % ISO 527-1/-2
Charpy impact strength, +23°C 70 / - kJ/m² ISO 179/1eU
Charpy impact strength, -30°C 60 / - kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 10 / - kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 10 / - kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature, 10°C/min 310 / * °C ISO 11357-1/-3
Glass transition temperature, 10°C/min 110 / * °C ISO 11357-1/-2
Temp. of deflection under load, 1.80 MPa 285 / * °C ISO 75-1/-2
Coeff. of linear therm. expansion, parallel 15 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 60 / * E-6/K ISO 11359-1/-2
Electrical propertiesdry / condUnitTest Standard
Dissipation factor, 100Hz 140 / 500 E-4 IEC 60250
Dissipation factor, 1MHz 140 / 500 E-4 IEC 60250
Volume resistivity >1E13 / 1E9 Ohm*m IEC 60093
Surface resistivity * / >1E15 Ohm IEC 60093
Electric strength 40 / - kV/mm IEC 60243-1
Comparative tracking index 600 / - - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 4 / * % Sim. to ISO 62
Humidity absorption 1.3 / * % Sim. to ISO 62
Density 1540 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
Viscosity number 105 / * cm³/g ISO 307, 1157, 1628
Diagrams
Stress-strain , Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
Stress-strain , Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
Secant modulus-strain , Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
Secant modulus-strain , Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
Tensile modulus-temperature , Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
Tensile modulus-temperature , Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
LTHA-Stress at Break 4mm, Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
LTHA-Strain at Break 4mm, Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
LTHA-Charpy Impact Strength (23°C) 4mm, Zytel® HTN92G45DH2 BK083, PA6T/66-GF45, DuPont
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Release agent
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding
PREPROCESSING

Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 100°C
Drying time, dehumidified dryer = 6-8 h
Processing moisture content = <0.1 %

PROCESSING

Melt temperature optimum = 325°C
Melt temperature range = 320-330°C
Mold temperature optimum = 95°C
Mold temperature range = 85-105°C


Moulding guide
Disclaimer
All data provided according to ISO 10350 for single points and ISO 11403 for multipoints.

Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
Test temperatures are 23°C unless otherwise stated.

The DuPont Oval Logo, DuPont™, The miracles of science™ and ® are trademarks or registered trademarks of DuPont Company.
Copyright© 2013 E.I. du Pont de Nemours and Company. All Rights Reserved.

The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication.
This information may be subject to revision as new knowledge and experience becomes available.
The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be
valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute
for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes.
Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection
with any use of this information.
Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights.
DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products.

CAUTION: DO NOT USE DUPONT MATERIALS IN MEDICAL APPLICATIONS INVOLVING IMPLANTATION IN THE HUMAN BODY OR
CONTACT WITH INTERNAL BODY FLUIDS OR TISSUES UNLESS THE MATERIAL HAS BEEN PROVIDED FROM DUPONT UNDER A
WRITTEN CONTRACT THAT IS CONSISTENT WITH DUPONT POLICY REGARDING MEDICAL APPLICATIONS AND EXPRESSLY
ACKNOWLEDGES THE CONTEMPLATED USE.

For further information, please contact your DuPont representative. You may also request a copy of DuPont POLICY Regarding Medical
Applications... H-50103-3 and DuPont CAUTION Regarding Medical Applications... H-50102-3.

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012