View list of
  • All DuPont grades
  • All PA612 grades
  • All grades beginning with Z

CAMPUS® datasheet | Zytel® LC6200 BK385


This datasheet of Zytel® LC6200 BK385 from DuPont Engineering Polymers is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

This datasheet includes:

  Zytel® LC6200 BK385 | PA612-I | DuPont Engineering Polymers
Rheological propertiesdry / condUnitTest Standard
Molding shrinkage (parallel) 2.8 / * % ISO 294-4, 2577
Molding shrinkage (normal) 1.1 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 1100 / 700 MPa ISO 527-1/-2
Yield stress 30 / 28 MPa ISO 527-1/-2
Yield strain 20 / 30 % ISO 527-1/-2
Nominal strain at break >50 / >50 % ISO 527-1/-2
Charpy notched impact strength (+23°C) 40 / 80 kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 15 / 15 kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 218 / * °C ISO 11357-1/-3
Temp. of deflection under load (1.80 MPa) 45 / * °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 85 / * °C ISO 75-1/-2
Other propertiesdry / condUnitTest Standard
Density 1000 / - kg/m³ ISO 1183
Diagrams
Stress-strain , Zytel® LC6200 BK385, PA612-I, DuPont
Stress-strain , Zytel® LC6200 BK385, PA612-I, DuPont
Secant modulus-strain , Zytel® LC6200 BK385, PA612-I, DuPont
Secant modulus-strain , Zytel® LC6200 BK385, PA612-I, DuPont
Tensile modulus-temperature , Zytel® LC6200 BK385, PA612-I, DuPont
Tensile modulus-temperature , Zytel® LC6200 BK385, PA612-I, DuPont
LTHA-Stress at Break 4mm, Zytel® LC6200 BK385, PA612-I, DuPont
LTHA-Strain at Break 4mm, Zytel® LC6200 BK385, PA612-I, DuPont
Characteristics
Processing
Film Extrusion, Profile Extrusion, Sheet Extrusion, Other Extrusion
Delivery form
Pellets
Regional Availability
Other text information
Injection molding
PREPROCESSING

Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 80°C
Drying time, dehumidified dryer = 3-4 h
Processing moisture content = <0.05 %

PROCESSING

Melt temperature optimum = 240°C
Melt temperature range = 230-250°C

Moulding guide
Disclaimer

E.I. du Pont de Nemours and Company is pleased to provide information about its products with the CAMPUS electronic database.

The information provided is gratis and DuPont assumes no obligation or liability for any advice furnished or for any results obtained with respect to this information.

All such advice is given and accepted at the risk of the buyer. The disclosure of information herein is not an express or implied license to operate under any patent of DuPont or others.

DuPont warrants that the use or sale of any material which is described herein and is offered for sale by DuPont does not infringe any patent covering the material itself, but does not warrant against infringement by reason of the use thereof in combination with other materials or the operation of any process.

Unless otherwise noted, the property values are for natural color (NC010) resins only. Colorants or other additives may alter some or all of the properties.
The data listed herein fall within the normal range of product properties and they should not be used to establish specification limits nor used alone as the basis of design.

Material Safety Data Sheets (SDSs) can be obtained from local sales offices.

Products listed herein should not be used in medical applications involving permanent implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont under a written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use.

For further information, please contact your DuPont representative.

You may also request a copy of DuPont policy regarding medical applications H-50103-2 and DuPont caution regarding medical applications H-50102-2.

Products listed herein may from time to time be modified or removed.
Please call your local sales office to determine current availability.


The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.