View list of
  • All DuPont grades
  • All PA66 grades
  • All grades beginning with Z

CAMPUS® datasheet | Zytel® MT409AHS NC010


This datasheet of Zytel® MT409AHS NC010 from DuPont Engineering Polymers is provided by the international plastics database CAMPUS.

CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.

This datasheet includes:

  Zytel® MT409AHS NC010 | PA66-I | DuPont Engineering Polymers
Product Texts
Common features of Zytel® nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness and toughness, good high temperature performance, good electrical and flammability properties, good abrasion and chemical resistance.

In addition, Zytel® nylon resins are available in different modified and reinforced grades to create a wide range of products with tailored properties for specific processes and end-uses. Zytel® nylon resin, including most flame retardant grades, offer the ability to be coloured.

The good melt stability of Zytel® nylon resin normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (-31kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.

Zytel® nylon resin typically is used in demanding applications in the automotive, furniture, domestic appliances, sporting goods and construction industry.

______________________________________________________


Zytel® MT409AHS is a unreinforced, heat stabilized and toughened polyamide 66 for injection molding and extrusion. It has high impact resistance at low temperature.

Rheological propertiesdry / condUnitTest Standard
Molding shrinkage (parallel) 2.0 / * % ISO 294-4, 2577
Molding shrinkage (normal) 1.9 / * % ISO 294-4, 2577
Mechanical propertiesdry / condUnitTest Standard
Tensile Modulus 2500 / 1000 MPa ISO 527-1/-2
Yield stress 62 / 41 MPa ISO 527-1/-2
Yield strain 4.5 / 30 % ISO 527-1/-2
Nominal strain at break 17 / >50 % ISO 527-1/-2
Tensile creep modulus (1000h) * / 820 MPa ISO 899-1
Charpy impact strength (+23°C) N / N kJ/m² ISO 179/1eU
Charpy impact strength (-30°C) N / N kJ/m² ISO 179/1eU
Charpy notched impact strength (+23°C) 19 / 40 kJ/m² ISO 179/1eA
Charpy notched impact strength (-30°C) 13 / 13 kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
Melting temperature (10°C/min) 263 / * °C ISO 11357-1/-3
Glass transition temperature (10°C/min) 80 / * °C ISO 11357-1/-2
Temp. of deflection under load (1.80 MPa) 66 / * °C ISO 75-1/-2
Temp. of deflection under load (0.45 MPa) 195 / * °C ISO 75-1/-2
Coeff. of linear therm. expansion (parallel) 100 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion (normal) 120 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.5 / * mm IEC 60695-11-10
UL recognition UL / * - -
Burning Behav. at thickness h HB / * class IEC 60695-11-10
Thickness tested 3.0 / * mm IEC 60695-11-10
UL recognition UL / * - -
Electrical propertiesdry / condUnitTest Standard
Relative permittivity (100Hz) 3.6 / 6.6 - IEC 60250
Relative permittivity (1MHz) 3.4 / 3.7 - IEC 60250
Dissipation factor (100Hz) 50 / 1800 E-4 IEC 60250
Dissipation factor (1MHz) 120 / 440 E-4 IEC 60250
Volume resistivity >1E13 / 3E10 Ohm*m IEC 60093
Surface resistivity * / >1E15 Ohm IEC 60093
Electric strength 23 / 22 kV/mm IEC 60243-1
Comparative tracking index 600 / - - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 4.9 / * % Sim. to ISO 62
Humidity absorption 1.4 / * % Sim. to ISO 62
Density 1100 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
Viscosity number 130 / * cm³/g ISO 307, 1157, 1628
Film Propertiesdry / condUnitTest Standard
Strain at yield (parallel) 4.4 / * % ISO 527-3
Rheological calculation propertiesValueUnitTest Standard
Density of melt 930 kg/m³ -
Thermal conductivity of melt 0.14 W/(m K) -
Spec. heat capacity melt 2730 J/(kg K) -
Ejection temperature 180 °C -
Diagrams
Viscosity-shear rate , Zytel® MT409AHS NC010, PA66-I, DuPont
Shearstress-shear rate , Zytel® MT409AHS NC010, PA66-I, DuPont
Dynamic Shear modulus-temperature , Zytel® MT409AHS NC010, PA66-I, DuPont
Dynamic Tensile modulus-temperature , Zytel® MT409AHS NC010, PA66-I, DuPont
Stress-strain , Zytel® MT409AHS NC010, PA66-I, DuPont
Stress-strain , Zytel® MT409AHS NC010, PA66-I, DuPont
Secant modulus-strain , Zytel® MT409AHS NC010, PA66-I, DuPont
Secant modulus-strain , Zytel® MT409AHS NC010, PA66-I, DuPont
Tensile modulus-temperature , Zytel® MT409AHS NC010, PA66-I, DuPont
Tensile modulus-temperature , Zytel® MT409AHS NC010, PA66-I, DuPont
LTHA-Stress at Break 4mm, Zytel® MT409AHS NC010, PA66-I, DuPont
LTHA-Strain at Break 4mm, Zytel® MT409AHS NC010, PA66-I, DuPont
Characteristics
Processing
Injection Molding, Profile Extrusion
Delivery form
Pellets
Additives
Release agent
Special Characteristics
Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding
PREPROCESSING
Drying Recommended = Yes, if moisture content of resin exceeds recommended level
Drying Temperature = 80°C
Drying Time, Dehumidified Dryer = 2-4h
Processing Moisture Content = <0.2 %
PROCESSING
Melt Temperature Optimum = 280°C
Melt Temperature Range = 270-300°C
Mold Temperature Optimum = 70°C
Mold Temperature Range = 50-90°C
Moulding guide
Chemical Media Resistance
Acids
Acetic Acid (5% by mass) (23°C)
Citric Acid solution (10% by mass) (23°C)
Lactic Acid (10% by mass) (23°C)
Hydrochloric Acid (36% by mass) (23°C)
Nitric Acid (40% by mass) (23°C)
Sulfuric Acid (38% by mass) (23°C)
Sulfuric Acid (5% by mass) (23°C)
Chromic Acid solution (40% by mass) (23°C)
Bases
Sodium Hydroxide solution (35% by mass) (23°C)
Sodium Hydroxide solution (1% by mass) (23°C)
Ammonium Hydroxide solution (10% by mass) (23°C)
Alcohols
Isopropyl alcohol (23°C)
Methanol (23°C)
Ethanol (23°C)
Hydrocarbons
n-Hexane (23°C)
Toluene (23°C)
iso-Octane (23°C)
Ketones
Acetone (23°C)
Ethers
Diethyl ether (23°C)
Mineral oils
SAE 10W40 multigrade motor oil (23°C)
SAE 10W40 multigrade motor oil (130°C)
SAE 80/90 hypoid-gear oil (130°C)
Insulating Oil (23°C)
Standard Fuels
ISO 1817 Liquid 1 (60°C)
ISO 1817 Liquid 2 (60°C)
ISO 1817 Liquid 3 (60°C)
ISO 1817 Liquid 4 (60°C)
Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23°C)
Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23°C)
Diesel fuel (pref. ISO 1817 Liquid F) (23°C)
Diesel fuel (pref. ISO 1817 Liquid F) (90°C)
Diesel fuel (pref. ISO 1817 Liquid F) (>90°C)
Salt solutions
Sodium Chloride solution (10% by mass) (23°C)
Sodium Hypochlorite solution (10% by mass) (23°C)
Sodium Carbonate solution (20% by mass) (23°C)
Sodium Carbonate solution (2% by mass) (23°C)
Zinc Chloride solution (50% by mass) (23°C)
Other
Ethyl Acetate (23°C)
Hydrogen peroxide (23°C)
DOT No. 4 Brake fluid (130°C)
Ethylene Glycol (50% by mass) in water (108°C)
1% nonylphenoxy-polyethyleneoxy ethanol in water (23°C)
50% Oleic acid + 50% Olive Oil (23°C)
Water (23°C)
Deionized water (90°C)
Phenol solution (5% by mass) (23°C)
Disclaimer

E.I. du Pont de Nemours and Company is pleased to provide information about its products with the CAMPUS electronic database.

The information provided is gratis and DuPont assumes no obligation or liability for any advice furnished or for any results obtained with respect to this information.

All such advice is given and accepted at the risk of the buyer. The disclosure of information herein is not an express or implied license to operate under any patent of DuPont or others.

DuPont warrants that the use or sale of any material which is described herein and is offered for sale by DuPont does not infringe any patent covering the material itself, but does not warrant against infringement by reason of the use thereof in combination with other materials or the operation of any process.

Unless otherwise noted, the property values are for natural color (NC010) resins only. Colorants or other additives may alter some or all of the properties.
The data listed herein fall within the normal range of product properties and they should not be used to establish specification limits nor used alone as the basis of design.

Material Safety Data Sheets (SDSs) can be obtained from local sales offices.

Products listed herein should not be used in medical applications involving permanent implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont under a written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use.

For further information, please contact your DuPont representative.

You may also request a copy of DuPont policy regarding medical applications H-50103-2 and DuPont caution regarding medical applications H-50102-2.

Products listed herein may from time to time be modified or removed.
Please call your local sales office to determine current availability.


The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991