View list of
CAMPUS® datasheet | Technyl® C 502XT
This datasheet of Technyl® C 502XT from Rhodia Polyamide Engineering Plastics is provided by the international plastics database CAMPUS.
Technyl® C 502XT | PA6 | Rhodia Polyamide Engineering Plastics
Texto del producto
Unreinforced polyamide 6, very high viscosity, for extrusion.
| Propiedades mecánicas | Seco / Cond | Unidades | Método de ensayo |
| Módulo de tracción | 2800 / 900 | MPa | ISO 527-1/-2 |
| Esfuerzo de fluencia | 80 / - | MPa | ISO 527-1/-2 |
| Alarg. en límite elástico | 4.1 / - | % | ISO 527-1/-2 |
| Alarg. nominal a rotura | >50 / - | % | ISO 527-1/-2 |
| Resistencia al impacto Charpy, +23°C | N / - | kJ/m² | ISO 179/1eU |
| Propiedades térmicas | Seco / Cond | Unidades | Método de ensayo |
| Temperatura de fusión, 10°C/min | 222 / * | °C | ISO 11357-1/-3 |
| Otras propiedades | Seco / Cond | Unidades | Método de ensayo |
| Absorción de humedad | 1.37 / * | % | Sim. to ISO 62 |
| Densidad | 1130 / - | kg/m³ | ISO 1183 |
Funciones
Características
Disponibilidad regional
Resistencia a medios químicos
Aviso
WARRANTY This information is supplied to assist you in your choice of the material best suited to your requirements and does not in any way constitute a product specification. The values given relate to unpigmented materials (natural colour). Pigmentation can alter results. The characteristics supplied are typical values. Our specialists are available to advise you on the values to be used in order to carry out calculations correctly on part dimensions. The information contained in this document is supplied in good faith. However it is given purely as an indication. It shall not be considered in any way as a formal commitment or warranty on our part, notably in respect of the eventual infringement of any rights of third parties who may use our products. We remain at your entire disposal to provide you with any information that you might require.
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012