View list of
- All Momentive Spec Chemicals grades
- All PF grades
- All grades beginning with B
CAMPUS® datasheet | Bakelite® PF 2560
This datasheet of Bakelite® PF 2560 from Momentive Specialty Chemicals is provided by the international plastics database CAMPUS.
Bakelite® PF 2560 | PF-X | Momentive Specialty Chemicals
Informations produit
Product description:
Phenolic moulding compound, inorganically/organically filled, average heat resistance, high surface quality, lower water absorption than PF 31, minimal distortion, UL listed moulding compound 1.5 mm / V-1 (ALL), 3.0 mm / V-0 (ALL).
Application areas:
Housings for domestic appliances, oven strips.| Property Name | Value | Unit | Standard No. |
|---|---|---|---|
| Apparent density (moulding compound) | 0.75 | g/cm³ | ISO 60 |
| Moulding shrinkage (injection moulding, longitudinal) | 0.75 | % | ISO 2577 |
| Post shrinkage (injection moulding, 168h/110°C) | 0.4 | % | ISO 2577 |
| Tensile strength (5mm/min) | 50 | MPa | ISO 527-1/2 |
| Compr. strength (test spec. flat tested) | 220 | MPa | ISO 604 |
| Flexural strength (2mm/min) | 90 | MPa | ISO 178 |
| Flexural modulus | 9000 | MPa | ISO 178 |
| Ball indentation hardness (H 961/30) | 350 | MPa | ISO 2039/P1 |
| Water absorption (24h/23°C) | 20 | mg | similar to ISO 62 |
| Additional characteristics: | A, EL, UL |
Preparation of Test Specimens of Thermosetting Moulding Compound
- Compression to ISO 295
- Injection to ISO 10724
Storage capability
2 years (relative humidity of 50-60% and maximum storage temperature of approximately 20°C)
| Propriétés rhéologiques | Valeur | Unité | Norme du test |
| Retrait au moulage, parallèle | 0.8 | % | ISO 294-4, 2577 |
| Propriétés mécaniques | Valeur | Unité | Norme du test |
| Module en traction | 9000 | MPa | ISO 527-1/-2 |
| Résistance au choc Charpy, +23°C | 6 | kJ/m² | ISO 179/1eU |
| Résistance au choc Charpy (entaillé), +23°C | 1.6 | kJ/m² | ISO 179/1eA |
| Propriétés thermiques | Valeur | Unité | Norme du test |
| Température de fléchissement s/chrg, 8.00 MPa | 115 | °C | ISO 75-1/-2 |
| Inflammabilité ep. nom. 1.5 mm | V-1 | class | IEC 60695-11-10 |
| Epaisseur de l'éprouvette | 1.5 | mm | IEC 60695-11-10 |
| Classement UL | UL | - | - |
| Inflammabilité pr. épaisseur h | V-0 | class | IEC 60695-11-10 |
| Epaisseur de l'éprouvette | 3.0 | mm | IEC 60695-11-10 |
| Classement UL | UL | - | - |
| Propriétés électriques | Valeur | Unité | Norme du test |
| Permittivité relative, 100Hz | 14.5 | - | IEC 60250 |
| Facteur de pertes, 100Hz | 0.2 | E-4 | IEC 60250 |
| Résistivité transversale | 1E9 | Ohm*m | IEC 60093 |
| Résistivité superficielle | 1E10 | Ohm | IEC 60093 |
| Rigidité diélectrique | 6 | kV/mm | IEC 60243-1 |
| Indice de résistance au cheminement | 125 | - | IEC 60112 |
| Propriétés diverses | Valeur | Unité | Norme du test |
| Masse volumique | 1590 | kg/m³ | ISO 1183 |
| Préparation et conditionnement des éprouvettes | Valeur | Unité | Norme du test |
| Injection, temp. de la matière plastif. | 115 | °C | ISO 10724 |
| Injection, vitesse d'injection | 170 | mm/s | ISO 10724 |
| Injection, pression de maintien | 100 | MPa | ISO 10724 |
| Injection, durée de recuit | 25 | min | ISO 10724 |
| Compression, température du moule | 160 | °C | ISO 295 |
| Compression, temps de recuit | 1 | min | ISO 295 |
Fonctions
Caractéristiques
Transformation
Moulage par injection, Moulage par transfert
Disponibilité régionale
Conditions générales
Momentive Specialty Chemicals GmbH
Gennaer Str. 2 - 4
58642 Iserlohn - Letmathe, Germany
Telefon +49 (0) 2374 / 925 280
Fax +49 (0) 2374 / 925 723
E-mail: michael.stahl@momentive.com
----------------------------------------------------------------------
Important Information
As international harmonization of testing procedures progresses,
previously used national standards are increasingly being replaced by
ISO (DIN EN ISO) standards.
All information, recommendations and suggestions provided by Bakelite AG
in the form of verbal or written communication, or in pertinent data
bases, represent our best knowledge and experience. Such data are
non-binding in character, and do not represent, either explicitly or
implicitly, assurances or a guarantee of specific properties. The
specified parameters merely represent typical data; they do not form a
basis for either a guarantee or a specification. The information,
recommendations and suggestions we provide describe our products and
possible applications in general or exemplary terms; they do not relate
to specific cases. The process of constant continued development and
improvement of our products can lead to changes in pertinent parameters,
texts and illustrations; no special mention is made of possible
alterations. Our technical advice does not free the customer of its
responsibility to verify our current information, in particular our
technical data sheets, safety data sheets and technical information
leaflets.
The customer will conduct its own tests of our products to determine
their suitability for the intended processes and uses, as well as to
establish that their processing properties are appropriate in the
pertinent situation, since our products may be used in a wide range of
technical applications that involve very different requirements
according to the specific situation. Therefore, such specific cases
are outside our control, and are the exclusive responsibility of the
customer. A pertinent agreement is necessary in case a binding assurance
of specific parameters is required. Customers and users of our products
must themselves observe possible patent rights, existing legislation
and regulations. This publication does not represent a license, nor
does it authorize infringement of any type of patent.
Note: This version supersedes and replaces all previous publications on
this subject. "Bakelite" is a registered brand of Bakelite AG in more
than 50 countries throughout the world. In the USA, "Bakelite" is a
registered brand of the Georgia Pacific Corporation. Bakelite AG is
licensed to use the brand name "Bakelite" for epoxy resins in the USA.
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012
CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012