View list of
  • All Ticona grades
  • All TPC grades
  • All grades beginning with R

CAMPUS® datasheet | RITEFLEX 663


This datasheet of RITEFLEX 663 from Ticona is provided by the international plastics database CAMPUS.

You may contact the supplier for more information about this grade.

This datasheet includes:

  RITEFLEX 663 | TPC | Ticona
Informations produit
Riteflex 663 is a nominal 63 Shore D thermoplastic polyester elastomer
with medium modulus.
Propriétés mécaniquesValeurUnitéNorme du test
Module en traction 360 MPa ISO 527-1/-2
Contrainte d'écoulement 22 MPa ISO 527-1/-2
Déformation au seuil d'écoulement 44 % ISO 527-1/-2
Déformation nominale à la rupture >50 % ISO 527-1/-2
Résistance au choc Charpy (entaillé), -30°C 22 kJ/m² ISO 179/1eA
Propriétés thermiquesValeurUnitéNorme du test
Température de fusion, 10°C/min 210 °C ISO 11357-1/-3
Température de fléchissement s/chrg, 0.45 MPa 114 °C ISO 75-1/-2
Coeffic. de dilatation therm. linéique, parallèle 180 E-6/K ISO 11359-1/-2
Inflammabilité pr. épaisseur h HB class IEC 60695-11-10
Epaisseur de l'éprouvette 1.5 mm IEC 60695-11-10
Propriétés électriquesValeurUnitéNorme du test
Permittivité relative, 1MHz 4 - IEC 60250
Facteur de pertes, 1MHz 400 E-4 IEC 60250
Résistivité transversale >1E13 Ohm*m IEC 60093
Rigidité diélectrique 14 kV/mm IEC 60243-1
Indice de résistance au cheminement 600 - IEC 60112
Propriétés diversesValeurUnitéNorme du test
Masse volumique 1240 kg/m³ ISO 1183
Caractéristiques
Transformation
Moulage par injection
Disponibilité régionale
Conditions générales
NOTICE TO USERS: Values shown are based on testing
of laboratory test specimens and represent data that fall
within the standard range of properties for natural material.
These values alone do not represent a sufficient basis for
any part design and are not intended for use in
establishing maximum, minimum, or ranges of values for
specification purposes. Colorants or other additives may
cause significant variations in data values.

Properties of molded parts can be influenced by a wide
variety of factors including, but not limited to, material
selection, additives, part design, processing conditions and
environmental exposure. Any determination of the
suitability of a particular material and part design for any
use contemplated by the users and the manner of such
use is the sole responsibility of the users, who must assure
themselves that the material as subsequently processed
meets the needs of their particular product or use.

To the best of our knowledge, the information contained in
this publication is accurate; however, we do not assume
any liability whatsoever for the accuracy and completeness
of such information. The information contained in this
publication should not be construed as a promise or
guarantee of specific properties of our products. It is the
sole responsibility of the users to investigate whether any
existing patents are infringed by the use of the materials
mentioned in this publication.

Moreover, there is a need to reduce human exposure to
many materials to the lowest practical limits in view of
possible adverse effects. To the extent that any hazards
may have been mentioned in this publication, we neither
suggest nor guarantee that such hazards are the only ones
which exist. We recommend that persons intending to rely
on any recommendation or to use any equipment,
processing technique, or material mentioned in this
publication should satisfy themselves that they can meet
all applicable safety and health standards.

We strongly recommend that users seek and adhere to the
manufacturer's current instructions for handling each
material they use, and to entrust the handling of such
material to adequately trained personnel only. Please call
the telephone numbers listed for additional technical
information. Call Customer Services for the appropriate
Materials Safety Data Sheets (MSDS) before attempting to
process our products.

The products mentioned herein are not intended for use in
medical or dental implants.

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012