View list of
CAMPUS® datasheet | Ultraform® W2320 003 Q600
This datasheet of Ultraform® W2320 003 Q600 from BASF is provided by the international plastics database CAMPUS.
You may contact the supplier for more information about this grade.
Ultraform® W2320 003 Q600 | POM | BASF
Testo del prodotto
Very free-flowing, rapidly solidifying grade for use where processing is extremely difficult but mechanical properties are lower.
Abbreviated designation according to ISO 1043: POM
Designation according to ISO 9988-1: POM-K, M-GNR, 05-002
Abbreviated designation according to ISO 1043: POM
Designation according to ISO 9988-1: POM-K, M-GNR, 05-002
| Proprietà Reologiche | Valore | Unitá | Norma del test |
| Indice di fusione di volume, MVR | 25 | cm³/10min | ISO 1133 |
| Temperatura | 190 | °C | ISO 1133 |
| Carico | 2.16 | kg | ISO 1133 |
| Proprietà Meccaniche | Valore | Unitá | Norma del test |
| Modulo a trazione | 2800 | MPa | ISO 527-1/-2 |
| Carico unitario a trazione | 65 | MPa | ISO 527-1/-2 |
| Deformazione a snervamento | 7.5 | % | ISO 527-1/-2 |
| Deformazione nominale a rottura | 24 | % | ISO 527-1/-2 |
| Modulo di scorrimento a trazione, 1h | 2100 | MPa | ISO 899-1 |
| Modulo di scorrimento a trazione, 1000h | 1350 | MPa | ISO 899-1 |
| Resistenza all'urto Charpy, +23°C | 150 | kJ/m² | ISO 179/1eU |
| Resistenza all'urto Charpy, -30°C | 150 | kJ/m² | ISO 179/1eU |
| Resist. urto Charpy con intaglio, +23°C | 5 | kJ/m² | ISO 179/1eA |
| Resist. urto Charpy con intaglio, -30°C | 4 | kJ/m² | ISO 179/1eA |
| Proprietà Termiche | Valore | Unitá | Norma del test |
| Temperatura di fusione, 10°C/min | 167 | °C | ISO 11357-1/-3 |
| Temp.di inflessione sotto carico, 1.80 MPa | 100 | °C | ISO 75-1/-2 |
| Temp.di inflessione sotto carico, 0.45 MPa | 156 | °C | ISO 75-1/-2 |
| Temp.di rammollimento Vicat, 50°C/h 50N | 150 | °C | ISO 306 |
| Coeff.di dilatazione termica lin., parallelo | 110 | E-6/K | ISO 11359-1/-2 |
| Reaz. al fuoco spess.nom. 1.5mm | HB | class | IEC 60695-11-10 |
| Spessore provato | 1.6 | mm | IEC 60695-11-10 |
| Omologazione UL | UL | - | - |
| Reazione al fuoco a spessore h | HB | class | IEC 60695-11-10 |
| Spessore provato | 0.8 | mm | IEC 60695-11-10 |
| Omologazione UL | UL | - | - |
| Indice di ossigeno | 15 | % | ISO 4589-1/-2 |
| Proprietà Elettriche | Valore | Unitá | Norma del test |
| Costante dielettrica relativa, 100Hz | 3.8 | - | IEC 60250 |
| Costante dielettrica relativa, 1MHz | 3.8 | - | IEC 60250 |
| Fattore di dissipazione, 100Hz | 10 | E-4 | IEC 60250 |
| Fattore di dissipazione, 1MHz | 50 | E-4 | IEC 60250 |
| Resistività volumica | 1E13 | Ohm*m | IEC 60093 |
| Resistività superficiale | 1E13 | Ohm | IEC 60093 |
| Rigidità dielettrica | 40 | kV/mm | IEC 60243-1 |
| Res. Alle correnti striscianti superficiali | 600 | - | IEC 60112 |
| Altre Proprietà | Valore | Unitá | Norma del test |
| Assorbimento d'acqua | 0.8 | % | Sim. alla ISO 62 |
| Assorbimento d'umidità | 0.2 | % | Sim. alla ISO 62 |
| Massa volumica | 1400 | kg/m³ | ISO 1183 |
| Proprietà reologiche per la simulazione | Valore | Unitá | Norma del test |
| Temperatura di estrazione | 110 | °C | - |
| Preparazione Provette | Valore | Unitá | Norma del test |
| Stamp. ad Iniezione, temp. di fusione | 200 | °C | ISO 294 |
| Stamp. ad Iniezione, temperatura dello stampo | 90 | °C | ISO 10724 |
| Stamp. ad Iniezione, velocità media d'iniezione | 200 | mm/s | ISO 294 |
Funzioni
Caratteristiche
Processabilità e Forma di Forni
Stampaggio ad Iniezione
Forma fisica disponibile
Pellet
Additivi
Agente di distacco
Disponibilità geografica
Resistenza chimica
Disclaimer
The data contained in this publication are based on our current
knowledge and experience. In view of the many factors that may affect
processing and application of our product, these data do not relieve
processors from carrying out their own investigations and tests. Any
descriptions, drawings, photographs, data, proportions, weights etc.
given herein may change without prior information and do not constitute
the agreed contractual quality of the product. It is the responsibility
of the recipient of our products to ensure that any proprietary rights
and existing laws and legislation are observed. NO WARRANTIES OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OFMERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS
DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE
PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING
THEINTELLECTUAL PROPERTY RIGHTS OF OTHERS.
In order to check the availability of products please contact us or our
sales agency.
For more information about our products contact your local BASF
representative or
BASF SE
Dept. PM/K
Fax: 0621-60-49497
e-mail: e-mail
CAMPUS® is a registered trademark of CWFG (Chemie
Wirtschaftsfoerderungsgesellschaft GmbH, Frankfurt)
knowledge and experience. In view of the many factors that may affect
processing and application of our product, these data do not relieve
processors from carrying out their own investigations and tests. Any
descriptions, drawings, photographs, data, proportions, weights etc.
given herein may change without prior information and do not constitute
the agreed contractual quality of the product. It is the responsibility
of the recipient of our products to ensure that any proprietary rights
and existing laws and legislation are observed. NO WARRANTIES OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OFMERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS
DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE
PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING
THEINTELLECTUAL PROPERTY RIGHTS OF OTHERS.
In order to check the availability of products please contact us or our
sales agency.
For more information about our products contact your local BASF
representative or
BASF SE
Dept. PM/K
Fax: 0621-60-49497
e-mail: e-mail
CAMPUS® is a registered trademark of CWFG (Chemie
Wirtschaftsfoerderungsgesellschaft GmbH, Frankfurt)
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012
CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012