View list of
Running a Numerical Search?
FREE DOWNLOAD
Interested inRunning a Numerical Search?
The CAMPUS desktop version
offers extended functionality!CAMPUS® datasheet | Ultramid® B3K
This datasheet of Ultramid® B3K from BASF is provided by the international plastics database CAMPUS.
CAMPUS is organized by a group of leading international resin producers, who have agreed to test their material according to uniform conditions, based on ISO standards (ISO 10350, ISO 11403), in order to offer comparable data to the market.
You may contact the supplier for more information about this grade.
Ultramid® B3K | PA6 | BASF
商品の説明文
Easy flowing, stabilized product for fast processing. Uses include technical parts with wall thicknesses > 2 mm (eg machinery components, fans, housings of hand-held power tools).
| レオロジー特性 | 乾燥/調湿 | 単位 | Test Standard |
| メルトボリュームレイト (MVR) | 160 / * | cm³/10min | ISO 1133 |
| 温度 | 275 / * | °C | ISO 1133 |
| 荷重 | 5 / * | kg | ISO 1133 |
| 機械的特性 | 乾燥/調湿 | 単位 | Test Standard |
| 引張弾性率 | 3000 / 1000 | MPa | ISO 527-1/-2 |
| 降伏応力 | 85 / 40 | MPa | ISO 527-1/-2 |
| 降伏ひずみ | 4.5 / 20 | % | ISO 527-1/-2 |
| 破壊呼びひずみ | 15 / >50 | % | ISO 527-1/-2 |
| 引張クリープ弾性率 (1h) | * / 900 | MPa | ISO 899-1 |
| 引張クリープ弾性率 (1000h) | * / 700 | MPa | ISO 899-1 |
| シャルピー衝撃強さ (+23°C) | N / N | kJ/m² | ISO 179/1eU |
| シャルピー衝撃強さ (-30°C) | 100 / - | kJ/m² | ISO 179/1eU |
| ノッチ付きシャルピー衝撃強さ (+23°C) | 5.5 / 60 | kJ/m² | ISO 179/1eA |
| ノッチ付きシャルピー衝撃強さ (-30°C) | 4 / - | kJ/m² | ISO 179/1eA |
| 熱的特性 | 乾燥/調湿 | 単位 | Test Standard |
| 溶融温度 (10°C/min) | 220 / * | °C | ISO 11357-1/-3 |
| ガラス転移点 (10°C/min) | 60 / * | °C | ISO 11357-1/-2 |
| 荷重たわみ温度 (1.80 MPa) | 65 / * | °C | ISO 75-1/-2 |
| 荷重たわみ温度 (0.45 MPa) | 180 / * | °C | ISO 75-1/-2 |
| ビカット軟化温度 (50°C/h 50N) | 204 / * | °C | ISO 306 |
| 線膨張係数 (平行) | 85 / * | E-6/K | ISO 11359-1/-2 |
| 1.5mm厚さでの燃焼性 | HB / * | class | IEC 60695-11-10 |
| 試験片の厚さ | 1.5 / * | mm | IEC 60695-11-10 |
| UL認定 | UL / * | - | - |
| 厚さhでの燃焼性 | V-2 / * | class | IEC 60695-11-10 |
| 試験片の厚さ | 3.0 / * | mm | IEC 60695-11-10 |
| UL認定 | UL / * | - | - |
| 酸素指数 | 26 / * | % | ISO 4589-1/-2 |
| 電気的特性. | 乾燥/調湿 | 単位 | Test Standard |
| 比誘電率 (100Hz) | 4 / - | - | IEC 60250 |
| 比誘電率 (1MHz) | 3.5 / 7 | - | IEC 60250 |
| 誘電正接 (100Hz) | 100 / - | E-4 | IEC 60250 |
| 誘電正接 (1MHz) | 230 / 3000 | E-4 | IEC 60250 |
| 体積抵抗率 | 1E13 / 1E10 | Ohm*m | IEC 60093 |
| 表面抵抗率 | * / 1E10 | Ohm | IEC 60093 |
| 耐トラッキング性 | - / 600 | - | IEC 60112 |
| 材料特有の特性 | 乾燥/調湿 | 単位 | Test Standard |
| 粘度数 | 150 / * | cm³/g | ISO 307, 1157, 1628 |
| 流動解析用データ | 値 | 単位 | Test Standard |
| 突き出し時の時の温度 | 145 | °C | - |
| 試験片の成形条件. | 値 | 単位 | Test Standard |
| 射出成形, 樹脂温度 | 250 | °C | ISO 294 |
| 射出成形, 金型温度 | 80 | °C | ISO 10724 |
| 射出成形, 射出速度 | 200 | mm/s | ISO 294 |
機能
耐薬品性
Disclaimer
The data contained in this publication are based on our current
knowledge and experience. In view of the many factors that may affect
processing and application of our product, these data do not relieve
processors from carrying out their own investigations and tests. Any
descriptions, drawings, photographs, data, proportions, weights etc.
given herein may change without prior information and do not constitute
the agreed contractual quality of the product. It is the responsibility
of the recipient of our products to ensure that any proprietary rights
and existing laws and legislation are observed. NO WARRANTIES OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OFMERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS
DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE
PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING
THEINTELLECTUAL PROPERTY RIGHTS OF OTHERS.
In order to check the availability of products please contact us or our
sales agency.
For more information about our products contact your local BASF
representative or
BASF SE
Dept. KS/KC
Fax: 0621-60-49497
e-mail: e-mail
CAMPUS® is a registered trademark of CWFG (Chemie
Wirtschaftsfoerderungsgesellschaft GmbH, Frankfurt)
knowledge and experience. In view of the many factors that may affect
processing and application of our product, these data do not relieve
processors from carrying out their own investigations and tests. Any
descriptions, drawings, photographs, data, proportions, weights etc.
given herein may change without prior information and do not constitute
the agreed contractual quality of the product. It is the responsibility
of the recipient of our products to ensure that any proprietary rights
and existing laws and legislation are observed. NO WARRANTIES OF ANY
KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OFMERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS
DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE
PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING
THEINTELLECTUAL PROPERTY RIGHTS OF OTHERS.
In order to check the availability of products please contact us or our
sales agency.
For more information about our products contact your local BASF
representative or
BASF SE
Dept. KS/KC
Fax: 0621-60-49497
e-mail: e-mail
CAMPUS® is a registered trademark of CWFG (Chemie
Wirtschaftsfoerderungsgesellschaft GmbH, Frankfurt)
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991
CAMPUS® is a Registered trademark of CWFG mbH, Frankfurt/Main, 1991













