View list of
CAMPUS® datasheet | Technyl® C 218 V15
This datasheet of Technyl® C 218 V15 from Rhodia Polyamide Engineering Plastics is provided by the international plastics database CAMPUS.
Technyl® C 218 V15 | PA6-GF15 | Rhodia Polyamide Engineering Plastics
제품 설명서
Polyamide 6, 15 % glass fibre reinforced, heat stabilised
| 기계적 특성 | 건조/응축 | 단위 | 시험규격 |
| 인장탄성률 | 6100 / 2900 | MPa | ISO 527-1/-2 |
| 파단시 강도 | 120 / - | MPa | ISO 527-1/-2 |
| 파단시 신율 | 4 / - | % | ISO 527-1/-2 |
| 챠피 충격 강도 , +23°C | 42 / - | kJ/m² | ISO 179/1eU |
| 챠피 노치드 충격 강도, +23°C | 5.5 / - | kJ/m² | ISO 179/1eA |
| 열적 특성 | 건조/응축 | 단위 | 시험규격 |
| 녹는점, 10°C/min | 222 / * | °C | ISO 11357-1/-3 |
| 유리 전이 온도, 10 °C/min | 55 / * | °C | ISO 11357-1/-2 |
| 하중하에서의 변형온도, 1.80 MPa | 180 / * | °C | ISO 75-1/-2 |
| 하중하에서의 변형온도, 0.45 MPa | 205 / * | °C | ISO 75-1/-2 |
| 선형 열팽창 계수, 평행 | 42 / * | E-6/K | ISO 11359-1/-2 |
| 두께 H인 제품의 난연성 | HB / * | class | IEC 60695-11-10 |
| 테스트 두께 | 1.6 / * | mm | IEC 60695-11-10 |
| 전기적 특성 | 건조/응축 | 단위 | 시험규격 |
| 상대 유전뮬, 1MHz | 3.8 / 4.5 | - | IEC 60250 |
| 소산 인자, 1MHz | 200 / - | E-4 | IEC 60250 |
| 부피 저항 | 1E13 / 1E9 | Ohm*m | IEC 60093 |
| 표면 저항 | * / 1E11 | Ohm | IEC 60093 |
| 전기 압력 | - / 22 | kV/mm | IEC 60243-1 |
| CTI | 475 / - | - | IEC 60112 |
도표
특징
생산 공정
사출 성형
특별 특성
열안정성
지역별 검색
화학적 매체에 대한 저항력
Disclaimer
WARRANTY This information is supplied to assist you in your choice of the material best suited to your requirements and does not in any way constitute a product specification. The values given relate to unpigmented materials (natural colour). Pigmentation can alter results. The characteristics supplied are typical values. Our specialists are available to advise you on the values to be used in order to carry out calculations correctly on part dimensions. The information contained in this document is supplied in good faith. However it is given purely as an indication. It shall not be considered in any way as a formal commitment or warranty on our part, notably in respect of the eventual infringement of any rights of third parties who may use our products. We remain at your entire disposal to provide you with any information that you might require.
The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH.
M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors.
Any decision about the application of materials must be double checked with the producer of this material.
CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012