  VESTODUR® X7095 nc (nf) | PBT-GF | Evonik Industries AG
제품 설명서
VESTODUR® X7095 nc


Resin: ISO 7792-PBT,MHR, A10-07,M30

 

VESTODUR® X7095 is a glass fiber reinforced semicrystalline thermoplastic resin for injection molding, based on

polybutylene terephthalate (PBT) with low warpage at parts made of this resin. The compound is suitable for the

manufacture of parts, which are subjected to high mechanical and thermal load.

유변학적 특성단위시험규격
용융 부피 - 흐름 속도, MVR 12 cm³/10min ISO 1133
온도 250 °C ISO 1133
하중 2.16 kg ISO 1133
성형 수축률, 평행 0.5 % ISO 294-4, 2577
성형 수축률, 수직 1.8 % ISO 294-4, 2577
기계적 특성단위시험규격
인장탄성률 7000 MPa ISO 527-1/-2
파단시 강도 105 MPa ISO 527-1/-2
파단시 신율 4 % ISO 527-1/-2
챠피 충격 강도 , +23°C 30 kJ/m² ISO 179/1eU
챠피 충격 강도, -30°C 30 kJ/m² ISO 179/1eU
챠피 노치드 충격 강도, +23°C 5.5 kJ/m² ISO 179/1eA
챠피 노치드 충격 강도, -30°C 4.5 kJ/m² ISO 179/1eA
열적 특성단위시험규격
녹는점, 10°C/min 223 °C ISO 11357-1/-3
유리 전이 온도, 10 °C/min 45 °C ISO 11357-1/-2
하중하에서의 변형온도, 1.80 MPa 195 °C ISO 75-1/-2
하중하에서의 변형온도, 0.45 MPa 220 °C ISO 75-1/-2
비카트 연화 온도, 50°C/h 50N 210 °C ISO 306
선형 열팽창 계수, 평행 60 E-6/K ISO 11359-1/-2
선형 열팽창 계수, 수직 70 E-6/K ISO 11359-1/-2
1.5mm 평균두께에서의 난연성 HB class IEC 60695-11-10
테스트 두께 1.6 mm IEC 60695-11-10
두께 H인 제품의 난연성 HB class IEC 60695-11-10
테스트 두께 0.8 mm IEC 60695-11-10
전기적 특성단위시험규격
상대 유전율, 100Hz 4 - IEC 60250
부피 저항 1E13 Ohm*m IEC 60093
표면 저항 1E14 Ohm IEC 60093
전기 압력 27 kV/mm IEC 60243-1
CTI 275 - IEC 60112
기타 특성단위시험규격
물에서의 흡수성 0.5 % ISO 62와 유사
밀도 1530 kg/m³ ISO 1183
테스트 견본 생산단위시험규격
ISO에 따른 공정 조건 7790 - ISO ....-2
사출성형: 용융수지온도 260 °C ISO 294
사출성형: 금형온도 80 °C ISO 10724
사출성형: 사출속도 200 mm/s ISO 294
사출성형: 유지압력 70 MPa ISO 294
특징
생산 공정
사출 성형
인도 유형
펠렛 (입자,알갱이)
부가물
이형제
특별 특성
열안정성
지역별 검색
Disclaimer
All listed technical data are typical values intended for your guidance.
They are given without obligation and do not constitute a materials
specification. Should you have any further questions concerning material
behavior or properties, please contact us at the following address :

for PA:           Evonik Industries AG
                     PP-HP-CRM
                     Gebäude 1227 / PB 16
                     D-45764 Marl
                     Phone: +49-(0)2365/49-2720
                     Fax:+49-(0)2365/49-2070
                     E-Mail: campusplastics@evonik.com

for PMMA:     Evonik Industries AG
                     Marketing / Campus
                     Kirschenallee
                     D-64293 Darmstadt
                     Germany
                     Phone: +49 - (0) 61 51 / 18-47 11
                     Fax: +49 - (0) 61 51 / 18-31 77
                     E-Mail: campusplastics@evonik.com
                     Internet: http://www.plexiglas-polymers.com

 

® = registered trademark

 

PLEXIGLAS® is a registered trademark of Evonik Röhm GmbH, Germany,

outside of the Americas. Within the Americas it is sold as ACRYLITE®,

which is a registered trademark of Evonik Cyro LLC, USA.

PLEXIMID® is a registered trademarks of Evonik Röhm GmbH, Germany.

CYROLITE® and XT® polymer are registered trademarks of Evonik Cyro LLC, USA.

 

This information and all further technical advice is based on our present knowledge

and experience. However, it implies no liability or other legal responsibility on our part,

including with regard to existing third party intellectual property rights, especially

patent rights. In particular, no warranty, whether express or implied, or guarantee of

product properties in the legal sense is intended or implied. We reserve the right to

make any changes according to technological progress or further developments. The

customer is not released from the obligation to conduct careful inspection and testing

of incoming goods. Performance of the product described herein should be verified by

testing, which should be carried out only by qualified experts in the sole responsibility

of a customer. Reference to trade names used by other companies is neither a

recommendation, nor does it imply that similar products could not be used.

 

NAFTA:

This information and all technical and other advice are based on Evonik’s

present knowledge and experience. However, Evonik assumes no liability for

such information or advice, including the extent to which such information or

advice may relate to third party intellectual property rights. Evonik reserves the

right to make any changes to information or advice at any time, without prior

or subsequent notice. EVONIK DISCLAIMS ALL REPRESENTATIONS AND

WARRANTIES, WHETHER EXPRESS OR IMPLIED, AND SHALL HAVE NO LIABILITY

FOR, MERCHANTABILITY OF THE PRODUCT OR ITS FITNESS FOR A PARTICULAR

PURPOSE (EVEN IF EVONIK IS AWARE OF SUCH PURPOSE), OR OTHERWISE.

EVONIK SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR

INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. It is the

customer’s sole responsibility to arrange for inspection and testing of all

products by qualified experts. Reference to trade names used by other

companies is neither a recommendation nor an endorsement of the

corresponding product, and does not imply that similar products could not be

used.

 

Sales range and technical data subject to alteration.

The CAMPUS internet database is hosted by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

CAMPUS® is a registered trademark of CWFG mbH, Frankfurt am Main, 2012