This datasheet of Bayblend® FR3030 from Bayer MaterialScience is provided by the international plastics database CAMPUS.

This datasheet includes:

  Bayblend® FR3030 | (PC+ABS) FR(40) | Bayer MaterialScience
材料文字说明
  • (PC+ABS) blend
  • unreinforced
  • flame-retardant
  • extrusion grade
  • Vicat/B 120 temperature = 115 °C
  • good extrusion and vacuum-forming behaviour
  • UL recognition 94 V-0 (1.5 mm)
  • halogen-free according to DIN VDE 0472-815
  • glow wire temperature (GWFI): 960 °C at 1.0 mm.
流变性能价值单位测试标准
熔体体积流动速度, MVR 11 cm³/10min ISO 1133
温度 260 °C ISO 1133
载荷 5 kg ISO 1133
机械性能价值单位测试标准
拉伸模量 2650 MPa ISO 527-1/-2
屈服应力 69 MPa ISO 527-1/-2
屈服伸长率 5 % ISO 527-1/-2
名义断裂伸长率 0 % ISO 527-1/-2
热性能价值单位测试标准
热变形温度, 1.80 MPa 98 °C ISO 75-1/-2
热变形温度, 0.45 MPa 106 °C ISO 75-1/-2
维卡软化温度, 50°C/h 50N 113 °C ISO 306
线性热膨胀系数, 平行 68 E-6/K ISO 11359-1/-2
线性热膨胀系数, 垂直 72 E-6/K ISO 11359-1/-2
1.5mm名义厚度时的燃烧性 V-0 class IEC 60695-11-10
测试用试样的厚度 1.5 mm IEC 60695-11-10
UL注册 UL - -
厚度为h时的5V燃烧性 5VB class IEC 60695-11-20
测试用试样的厚度 2.0 mm IEC 60695-11-20
UL注册 UL - -
电性能价值单位测试标准
相对介电常数., 100Hz 3.2 - IEC 60250
相对介电常数., 1MHz 3.1 - IEC 60250
介质损耗因子, 100Hz 37 E-4 IEC 60250
介质损耗因子, 1MHz 75 E-4 IEC 60250
体积电阻率 >1E13 Ohm*m IEC 60093
表面电阻率 >1E15 Ohm IEC 60093
介电强度 35 kV/mm IEC 60243-1
相对漏电起痕指数 350 - IEC 60112
其它性能价值单位测试标准
吸水性 0.5 % 类似ISO 62
吸湿性 0.2 % 类似ISO 62
密度 1190 kg/m³ ISO 1183
流变计算用参数价值单位测试标准
熔体密度 975 kg/m³ -
熔体 0.169 W/(m K) -
熔体的比热 2000 J/(kg K) -
有效导热率a 8.67E-8 m²/s -
喷射温度 120 °C -
试样制备条件价值单位测试标准
注塑, 熔体温度 260 °C ISO 294
注塑, 模具温度 80 °C ISO 10724
注塑, 注射速度 240 mm/s ISO 294
函数
粘度-剪切速度 , Bayblend® FR3030, (PC+ABS) FR(40), Bayer MatSc
剪切应力-剪切速度 , Bayblend® FR3030, (PC+ABS) FR(40), Bayer MatSc
应力-应变.  , Bayblend® FR3030, (PC+ABS) FR(40), Bayer MatSc
正割模量-应变.  , Bayblend® FR3030, (PC+ABS) FR(40), Bayer MatSc
典型数据
加工方法
异型材挤出成型, 片材挤出成型, 压延成型, 热成型
供货形式
粒料
添加剂
脱模助剂
地区供应
权利义务的法律声明

Bayer MaterialScience AG

The manner in which you use and the purpose to which you put and utilize our products, technical assistance and information (whether verbal, written or by way of production evaluations), including any suggested formulations and recommendations, are beyond our control. Therefore, it is imperative that you test our products, technical assistance and information to determine to your own satisfaction whether they are suitable for your intended uses and applications. This application-specific analysis must at least include testing to determine suitability from a technical as well as health, safety and environmental standpoint. Such testing has not necessarily been done by us. Unless we otherwise agree in writing, all products are sold strictly pursuant to the terms of our standard conditions of sale which are available upon request. All information and technical assistance is given without warranty or guarantee, and is subject to change without notice. It is expressly understood and agreed that you assume and hereby expressly release us from all liability, in tort, contract or otherwise, incurred in connection with the use of our products, technical assistance and information. Any statement or recommendation not contained herein is unauthorized and shall not bind us. Nothing herein shall be construed as a recommendation to use any product in conflict with patents covering any material or its use. No license is implied or in fact granted under the claims of any patent. Unless specified to the contrary, the property values given have been established on standardized test specimens at room temperature. The figures should be regarded as typical values only and not as binding limiting values. Please note that the properties can be affected by the design of the mold/die, the processing conditions and coloring. With respect to health, safety and environment precautions, the relevant Material Safety Data Sheets (MSDS) and product labels must be observed prior to working with our products.


BMS Medical Grades

BMS Products that are designated as "Medical Grade", e.g., plastics, sheets, and films, meet certain biocompatibility test requirements of ISO Standard 10993-1: "Biological Evaluation of Medical Devices" for the categories including: 1) skin contact, 2) up to 24 hours contact with circulating blood, tissue, bone, and dentin, 3) up to 30 days contact with mucosal membranes, compromised surfaces, and blood path, indirect. BMS Products designated as "Medical Grade" shall not be considered candidates for the following types of Medical Applications unless BMS explicitly agrees, in writing, to sell such products for such applications: a) cosmetic, reconstructive, or reproductive implant applications; b) any other bodily implant applications; c)applications involving contact with or storage of human tissue, blood, or other bodily fluids, for greater than 30 days; or d) applications having greater than 24 hours contact with circulating blood, tissue, bone and dentin. The biocompatibility testing referenced above cannot assure the biocompatibility of final or intermediate products made from BMS Products or the suitability of such products for their use in a Medical Application, i.e., the test data cannot be used to conclude that any medical devices manufactured from the BMS Products meet the necessary requirements of ISO Standard 10993-1. It is the sole responsibility of the manufacturer of final end-use product to conduct all necessary tests (including biocompatibility tests) and inspections and to evaluate the final product under actual end-use requirements. The designation as "Medical Grade" does not mean that BMS or anyone else has determined that the product is suitable for use in any particular Medical Application. BMS makes no representations regarding the suitability of a BMS Product for a particular Medical Application or final enduse product. A determination that the BMS Product is suitable for use in a particular Medical Application or final end-use product can only be made by the purchaser of the BMS product who utilizes it in a Medical Application and conducts all necessary testing and evaluation to support such a determination.


Appropriate Use of BMS Products in a Medical Application

BMS has not performed clinical medical studies concerning the use of BMS Products. Moreover, BMS has neither sought nor received approval from the United States Food and Drug Administration (FDA) or other competent authorities from other regions for the use of BMS Products in a Medical Application. BMS makes no representations or warranty regarding (and accepts no responsibility for determining) either: (a) the suitability of a BMS Product for a particular Medical Application or final end-use product or (b) the adequacy of any warning relating to a BMS Product or particular Medical Application or final end-use product. The suitability of BMS Products in a given end-use environment is dependent upon various conditions including, without limitation, chemical compatibility, method of manufacture, temperature, part design, sterilization method, residual stresses, and external loads. It is the sole responsibility of the manufacturer of the final end-use product to determine the suitability (including biocompatibility) of all raw materials and components, including any BMS Products, in order to ensure that the final product: - meets relevant biocompatibility requirements and is otherwise safe for its end-use, - performs or functions as intended, - is suitable for its intended use, and - complies with all applicable FDA and other regulatory requirements. It also is the sole responsibility of the manufacturer of the final end-use product to conduct all necessary tests and inspections and to evaluate the final product under actual end-use requirements and to adequately advise and warn purchasers, users, and/or learned intermediaries (such as physicians) of pertinent risks and fulfill any postmarket surveillance obligations. Any decision regarding the appropriateness of a particular medical product in a particular clinical or Medical Application should be based on the judgment of the manufacturer, seller, the competent authority, and the treating physician. BMS cannot weigh the benefits against the risks of a medical device and cannot offer a medical or legal judgment on the safety or efficacy of the use of a BMS Product in a specific Medical Application. Terms in capital letters as used herein shall have the same meaning as defined in the "GUIDANCE ON USE OF BAYER MATERIALSCIENCE PRODUCTS IN A MEDICAL APPLICATION" which can be found under (see here). It is the customer's responsibility to thoroughly review the Guidance Document in detail and to diligently consider its content prior to any use of BMS Products in Medical Applications. For further information on our Medical Grades please see our brochure "Makrolon, Apec and Bayblend for medical devices".

www.bayerplastics.com